![TPI PM18-S Owner'S Manual Download Page 2](http://html1.mh-extra.com/html/tpi/pm18-s/pm18-s_owners-manual_1146213002.webp)
Issue Date: 05-01-03
OIPM P/N 8914 Page 2 of 3
6
SET-UP INSTRUCTIONS
1. Remove unit from carton making sure
to locate water supply line and filter
assembly.
2. Attach water supply hose with filter
assembly to the pump.
3. Fill cooler with clean fresh water and
install fan and pump unit on cooler
(making sure that the supply hose goes
toward the bottom of the cooler).
4. Plug the GFCI safety plug directly into
a 120-volt A.C. 60 Hz grounded
electrical Power supply.
Note
: Improper voltage will burn out motor
and pump windings and void warranty.
GFCI SAFETY PLUG TEST
The GFCI safety plug provides added safety for using
this cooler for indoors or outside environments.
x
Test the GFCI safety plug before each use.
x
Plug GFCI into a power outlet – the indicator
will show power is available.
x
Press the test button – indicator will turn off.
x
Press reset button before use.
Note: Do Not Use If Above Test Fails.
OPERATING INSTRUCTIONS
1. Always make sure the unit is operated on a
level surface. The PM-18 unit has built in tip
over switch in the pump to remove power
from the unit in the event of a 35-degree tilt
or more. The PM-24 unit has a temperature
sensor to shut off water pump if no water is
flowing through pump for cooling.
2. Recommend the use of fresh water for daily
operations.
3. Caution do not operate pump without proper
water level or with no water unless you are
using the fan only option.
4.
Check for leaks. If there are any leaks turn off
pump and reinsert tubing or hand tighten the
fitting that were leaking.
PROPER MAINTENANCE
Check filter assembly occasionally. Replace if
it becomes clogged.
Clogged nozzles – remove, and place in a
cleaner overnight in a scale and lime-
removing product. Flush line for a few
seconds then re-install nozzle. Use spare
nozzles as required. Note: Hand-tighten
nozzles only.
Recommend regular cleaning of unit with an
anti-bacterial agent. This includes the water
storage unit or cooler.
Cover the unit when not in use.
ELECTRICAL SHOCK
HAZARD
.
x
Serious injury or death
possible.
x
Disconnect from
electrical supply before
filling, servicing, or
moving product.
x
Test GFCI per
instructions on this
page before using
product.