706

Rev. 6.X Analyzers

CO Analyzer

The Value Leader

TM

w

w

w

.

G

lo

ba

lT

es

tS

up

pl

y

.c

om

Fi

nd

 Q

ua

lit

Pr

od

uc

ts

 O

nl

in

at

:

sa

le

s@

G

lo

ba

lT

es

tS

up

pl

y.

co

m

Summary of Contents for 706

Page 1: ...4 Beaverton OR 97005 Tel 503 520 9197 Fax 503 520 1225 www tpi thevalueleader com Test Products International Ltd 342 Bronte Road South Unit 9 Milton Ontario Canada L9T5B7 Tel 905 693 8558 Fax 905 693 0888 706 Rev 6 X Analyzers CO Analyzer The Value LeaderTM ...

Page 2: ...cations Power Supply 4 AA Alkaline Batteries Sensor Long Life Electrochemical Range O to 9 999 ppm Resolution 1ppm 0 to 9999ppm 0 001 9999ppm Accuracy 5 ppm or 5 of reading whichever is greater Warm up Approx 30 seconds Response time 90 of reading 120 seconds Duty Cycle 30 minutes Battery Life Approx 30 hrs Size 3 75 x 8 0 x 3 0 95 x 203 x 76 mm Weight 1 1 lbs 500g Probe Length 9 230mm Tube Length...

Page 3: ...able General Description The 706 is an advanced state of the art carbon monoxide CO gas analyzer designed to provide part per million readings from 0 10 000 ppm The 706 is capable of performing ambient as well as flue gas checks with its hot air probe and internal pump The 706 is utilizes an advanced long life electrochemical sensor that can be field calibrated and has a low replacement cost Featu...

Page 4: ...on of your analyzer Follow the instructions carefully 1 Press and hold the FUNC and Down Arrow keys for approximately 5 seconds until a beep is heard Press and hold the Scroll Enter Key down until FILD CAL is displayed The 706 will cycle through a 30 second countdown then display CAL Air gAS 2 Use the Up Arrow Key to select Air by making it blink Press the Scroll Enter Key to accept the selection ...

Page 5: ... changing the auto power off mode press the Func Key Otherwise press the Up and Down Arrow Keys to enable En or disable dis the auto off function Factory default is enabled En Press the Scroll Enter Key to accept the selection 8 706 Display CAL StoP go Action Press the Up Arrow Key to select StoP by making it blink and press the Scroll Enter Key to accept the selec tion The 708 will return to norm...

Page 6: ...e Func Key Otherwise press the Up and Down Arrow Keys to enable En or disable dis the auto off function Factory default is enabled En Press the Scroll Enter Key to accept the selection 8 706 Display CAL StoP go Action Press the Up Arrow Key to select StoP by making it blink and press the Scroll Enter Key to accept the selec tion The 708 will return to normal operation Operating Instructions A Powe...

Page 7: ...ecall button once 2 The display will show Stor and Cal Use the Arrow buttons to select the desired function Stor Selecting Stor allows you to display the information in a memory location 1 Press the Recall button once The display will show Stor and Cal Using the Arrow buttons select Stor by making it blink Press the Scroll Enter button 2 Addr will be displayed and a number from 0 to 49 will flash ...

Page 8: ...ode If Cal print mode is selected the analyzer will display Wait out and bars will change position on the LCD until printing is com plete After printing is complete End will be displayed and YES or no will blink Selecting YES will return the 706 to normal operation selecting no will return the 706 to the print selection screen so you can print again Use the Up and Down Arrow Keys to make the selec...

Page 9: ...LCD until printing is complete CAL Print Mode If Cal print mode is selected the analyzer will display Wait out and bars will change position on the LCD until printing is com plete After printing is complete End will be displayed and YES or no will blink Selecting YES will return the 706 to normal operation selecting no will return the 706 to the print selection screen so you can print again Use th...

Page 10: ...Stor and Cal Use the Arrow buttons to select the desired function Stor Selecting Stor allows you to display the information in a memory location 1 Press the Recall button once The display will show Stor and Cal Using the Arrow buttons select Stor by making it blink Press the Scroll Enter button 2 Addr will be displayed and a number from 0 to 49 will flash 3 Using the up and down arrows select the ...

Page 11: ...oll Enter button and Addr and a number from 0 to 49 will flash 3 Using the up and down arrows select the desired location to save the readings 4 Press the Scroll Enter key once The 706 will store the read ings End will be displayed and Yes will flash Press the Scroll Enter button if you are finished printing or use the Arrow buttons to select No to print again Appendix C ERROR CODES TROUBLESHOOTIN...

Page 12: ...e Func Key Otherwise press the Up and Down Arrow Keys to enable En or disable dis the auto off function Factory default is enabled En Press the Scroll Enter Key to accept the selection 8 706 Display CAL StoP go Action Press the Up Arrow Key to select StoP by making it blink and press the Scroll Enter Key to accept the selec tion The 708 will return to normal operation Operating Instructions A Powe...

Page 13: ...tion mode can adversely affect the operation of your analyzer Follow the instructions carefully 1 Press and hold the FUNC and Down Arrow keys for approximately 5 seconds until a beep is heard Press and hold the Scroll Enter Key down until FILD CAL is displayed The 706 will cycle through a 30 second countdown then display CAL Air gAS 2 Use the Up Arrow Key to select Air by making it blink Press the...

Page 14: ...anced state of the art carbon monoxide CO gas analyzer designed to provide part per million readings from 0 10 000 ppm The 706 is capable of performing ambient as well as flue gas checks with its hot air probe and internal pump The 706 is utilizes an advanced long life electrochemical sensor that can be field calibrated and has a low replacement cost Features include IR printer port to print hard ...

Page 15: ... the CO Sensor Appendix F CO Chart Specifications Power Supply 4 AA Alkaline Batteries Sensor Long Life Electrochemical Range O to 9 999 ppm Resolution 1ppm 0 to 9999ppm 0 001 9999ppm Accuracy 5 ppm or 5 of reading whichever is greater Warm up Approx 30 seconds Response time 90 of reading 120 seconds Duty Cycle 30 minutes Battery Life Approx 30 hrs Size 3 75 x 8 0 x 3 0 95 x 203 x 76 mm Weight 1 1...

Page 16: ...706 Rev 6 X Analyzers CO Analyzer The Value LeaderTM www tpi thevalueleader com www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...