TPI 3480/RCH Series Installation Instructions Download Page 3

FORM: 9480 ECO 1-7255 REV. 01/17

3 OF 4

3480 / RCH SERIES CEILING HEATER

CAUTION: 

To avoid the risk of fire, shock or personal injury; 

do not insert or allow any foreign objects or hands to enter 

any ventilation or exhaust openings.

THERMAL CUTOUT IDENTIFICATION

All 480V Models employ a automatic limit control. 208, 

240 and 277V models have a capillary manual reset 

limit control.   

Models with capillary type manual reset limit control.

This device is located on the heater venturi (bottom of 

unit as installed) with the capillary routed around the 

outside of the element assembly.

THERMAL CUTOUT OPERATION

(WITH CAPILLARY MANUAL RESET)

To  reset  thermal  cutout,  first  disconnect  power  from   

the unit allowing time to cool, locate the two 1/4” dia. 

openings in the front grille. Using a small screwdriver 

or pencil press the reset button (with minimal amount 

of force) through the 1/4” opening, then restore power 

to the unit. If fault continues disconnect power and 

check for causes.

THERMAL CUTOUT 

(480 volt models)

If for any reason temperatures increase beyond normal 

limits, safety thermal limit will open de-energizing 

heating element and fan motor.  Check entire installation 

to determine cause of overheating and take corrective 

measures.  The limit control is the automatic reset type 

and after cooling will reset, allowing heater to resume 

operation.

OPERATION

1

.Turn on the power supply to heater.

2.Rotate thermostat knob fully clockwise.  

3.Allow the room to reach desired temperature, then rotate thermostat knob counter clockwise  until the heater de-energizes.

MAINTENANCE AND CLEANING
DISCONNECT POWER BEFORE ATTEMPTING ANY SERVICE

The heater should be cleaned  at least annually to prevent excess build-up of dirt and lint accumulated under normal 

operating conditions. In an unusually dirty environment the cleaning should be done more often. Using a vacuum cleaner 

with soft brush attachment, clean the the intake and discharge openings of any accumulated dirt or lint.  The fan blade and 

elements may be cleaned after removing the front cover. The face plate can be cleaned with damp cloth and mild detergent.

The factory installed louvered diffuser  can be adjusted to 

direct air flow as desired. If necessary the louvered diffuser 

can be rotated 90 degrees by removing the four mounting 

screws  and  turning  the  louvered  diffuser  to  the  desired 

position and attaching to the grille. Care must be taken to 

align the notched corners of the diffuser frame with the reset 

holes in the grille. The louvered diffuser cannot be used in 

conjunction with the standard circular outlet.

OPTIONAL LOUVERED DIFFUSER