m. Two-Hold System
The two-hold system is a data hold feature that will
automatically store a stable reading under the 1
HOLD sub-display in the lower left hand corner of
the LCD. When a new, stable reading is obtained,
the reading under 1 HOLD will be moved to 2 HOLD
and the new reading will be displayed under 1
HOLD.
Depress the
HOLD
button to activate the feature.
Push the button again to de-activate the feature.
l. Relative % Mode
The Relative % mode takes the actual reading on
the main display and compares it to a reference
value programmed by the user on the right hand
sub-display. The left hand sub-display will show the
percentage the actual reading varies from the refer-
ence value. Activate the function as follows:
1.
To use
Relative %
mode manually select the
range for the function.
2.
Depress the
REL%
button.
3.
Depress the
EDIT
button. The right hand digit
under the
REF
sub-display will start to flash.
4.
Depress
REL%
or
HOLD
buttons until correct
number is selected for that display position.
5.
Depress the
REC
button. The next digit to the
right of 3 above will start to flash.
6.
Repeat steps 4 and 5 until correct values for
all four digits under
REF
sub-display are
entered.
7.
After the correct
REF
value is entered, depress
the
EDIT
button.
8.
Measure the circuit or component being com-
pared to the programmed reference value.
Results will be displayed as a percentage in the
lower left hand sub display.
9.
Depress the
REL%
button or turn the rotary
switch to exit the function.