8
d. ACA
Range
Resolution
Accuracy
Overload Protection
200µA0.1µA
±1% of reading,
Fuse*
2mA0.001mA
±3 digits
F600V, 2A, 31CM
20mA0.01mA
200mA0.1mA
±1.8% of reading,
2A0.001A
±3 digits
10A0.01A ± 3% of reading, ± 7 digits
Fuse* F600V, 10A, 31CM
e. OHM (Resistance, )
Range
Resolution
Accuracy
Overload Protection
200
0.1
±0. 5% of reading,
600V DC or
2k
0.001k
±1 digit
AC Peak
20k
0.01k
200k
0.1k
2M
0.001M
20M
0.01M
±1% of reading, ±2 digits
f. Diode Test
Test Voltage
Max Test Current
Over Load Protection
2.5V
Approx. 1mA
600 V DC or Peak AC
g. Continuity Buzzer
Test Voltage
Threshold
Over Load Protection
2.5V
<100
600 V DC or Peak AC
h. General Specifications
Power Supply
9 Volt Battery
Battery Life
560 hrs. Alkaline
Size (H x L x W)
33mm x 86mm x 187mm
(1.3” x 3.4” x 7.4”)
Weight
340g (12 oz)
3.
Specifications
IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2
a. DCV
Range
Resolution
Accuracy
Impedance
200mV
0.1mV
±0.5% of reading,
10M
2V
0.001V
±2 digits
20V
0.01V
200V
0.1V
1000V
1V
b. ACV (45Hz to 450Hz)
Range
Resolution
Accuracy
Impedance
200mV
0.1mV
±1.2% of reading,
10M
±3 digits
2V
0.001V
±0.8% of reading,
20V
0.01V
±3 digits
200V
0.1V
750V
1V
c. DCA
Range
Resolution
Accuracy
Overload
Protection
200µA0.1µA
±0.5% of reading,
Fuse*
2mA0.001mA
±1 digit
F600V, 2A, 31CM
20mA0.01mA
200mA0.1mA
±1.2% of reading,
2A0.001A
±1 digit
10A0.01A ±2% of reading,
Fuse*
±5 digits
F600V, 10A, 31CM
9
*Warning:
Use only correct size, voltage and current rated fuses.
Test Leads: Use only correct type and overvoltage category rating.
*Warning:
Use only correct size, voltage and current rated fuses.
Test Leads: Use only correct type and overvoltage category rating.
UL 3111-1
www.
GlobalTestSupply
.com
Find Quality Products Online at: