8
d. ACA
Range
Resolution
Accuracy
Overload Protection
400µA
0.1µA
±0. 8% of reading,
Fuse
4000µA 1µA
±3 digits
0.5Amp/600V
40mA
0.01mA
400mA
0.1mA
e. OHM (Resistance,
Ω
)
Range
Resolution
Accuracy
Overload Protection
400
Ω
0.1
Ω
±0. 5% of reading,
600V DC or
4k
Ω
0.001k
Ω
±3 digits
AC Peak
40k
Ω
0.01k
Ω
400k
Ω
0.1k
Ω
4M
Ω
0.001M
Ω
±1% of reading,
40M
Ω
0.01M
Ω
±3 digits
f. Diode Test
Test Voltage
Max Test Current
Over Load Protection
3V
Approx. 30µA
600 V DC or Peak AC
g. Continuity Buzzer
Test Voltage
Threshold
Over Load Protection
3V
< 50
Ω
600 V DC or Peak AC
h. General Specifications
Max. Volt. between
1000V
any Input and Ground
Fuse Protection
mA:
0.5Amp/600VAC
Display Type
4,000 Count, 2 times per second update
Operating Temp.
0° to 40°C (32° to 104°F)
Storage Temp.
-10° to 50°C (14° to 122°F)
Relative Humidity
0% to 80%
Power Supply
2 Each 1.5 Volt “AA” Batteries
Battery Life
200 hrs. Typical
Size (H x L x W)
33mm x 86mm x 187mm (1.3in x 3.4in x 7.4in)
Weight
340g (12oz)
3.
Specifications
IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2
a. DCV
Range
Resolution
Accuracy
Impedance
400mV
0.1mV
±0.3% of reading,
10M
Ω
4V
0.001V
±3 digits
40V
0.01V
400V
0.1V
1000V
1V
b. ACV (45 to 450 Hz)
Range
Resolution
Accuracy
Impedance
4V
0.001V
±0.8% of reading,
10M
Ω
40V
0.01V
±3 digits
400V
0.1V
750V
1V
c. DCA
Range
Resolution
Accuracy
Overload Protection
400µA
0.1µA
±0.8% of reading,
Fuse
4mA
0.001mA
±3 digits
0.5Amp/600V
40mA
0.01mA
400mA
0.1mA
9
UL 3111-1
*Warning:
Use only correct size, voltage and current rated fuses.
Test Leads: Use only correct type and overvoltage category rating.
www.
.com