9
8
STEP BY STEP PROCEDURES
b.Measuring AC Volts
WARNING!
Do not attempt to make a voltage
measure-
ment of more than 600V or of a voltage level that
is unknown.
Instrument set-up:
FUNC
BLACK RED
MIN
MAX
TEST LEAD TEST LEAD
READING
READING
ACV COM
V
Ω
0.001V
600V
Measurement Procedure:
1.
Disconnect power to circuit to be meas-
ured.
2.
Plug the black test lead into the
COM
input
jack.
3
Plug red test lead into
V/
Ω
Ω
input jack.
4.
Set rotary switch on 120 to desired range
in
ACV
function depending on the voltage
to be measured.
5.
Connect the test leads to the circuit to be
measured.
6.
Reconnect power to the circuit to be
measured.
7.
Read the voltage on the 120.
c. Measuring Resistance
WARNING!
Do not attempt to make resistance measurements
with circuit energized. For best results, remove
resistor completely from circuit before attempting
to measure.
NOTE:
To make accurate low ohm measurements, short ends of test
leads together and record resistance reading. Deduct this
value from actual readings.
Instrument set-up:
FUNC
BLACK RED
MIN
MAX
TEST LEAD TEST LEAD
READING
READING
OHM COM
V
Ω
1
Ω
2.000k
Ω
Measurement Procedure:
1. Disconnect power to the circuit to be meas-
ured.
2. Plug the black test lead into the
COM
input
jack.
3. Plug the red test lead into the
V/
Ω
Ω
input jack.
4. Set rotary switch on the 120 to
2k
Ω
Ω
function
depending on the voltage to be measured.
5. Connect the test leads to the circuit to be
measured.
6. Read the resistance value on the 120.
STEP BY STEP PROCEDURES