HEATER INSTALLATION continued
SUSPENSION ALTERNATIVES
Your OCH series heater can be mounted with either the
adjustable mounting brackets or by chain suspension.
Both mounting options are included with the heater in
the hardware package.
Standard Mounting:
In the hardware bag shipped with your heater you
will find two adjustable mounting brackets and
fastening hardware. Using the mounting centers
specified in figures 1 & 2, mount your adjustable
mounting brackets (bends to the inside). Once
mounted, assemble the heater to brackets (figure 3)
with mounting hardware, these brackets enable the
heater to be angled in 15-degree increments up to
45 degrees.
Chain Suspension:
The heater can also be chain-hung as shown in
figure 4.
Cut the 16ga. chains (two 4 foot chains are
provided) to desired length. Attach chains to heater
with “S”-hooks provided and suspend from overhead
structure. Crimp “S”-hooks closed after assembly.
Install heater so that the quartz tubes are horizontal.
Failure to do this may cause the heating element within
the tube to sag and cause premature burnout
ELECTRIC SHOCK HAZARD
• Serious injury or death may occur.
• Disconnect from electrical supply
before installing or servicing this
heater.
• Read and follow installation clearance
requirements on page 4.
3.000
0° TO 45° AT
15° INCREMENTS
3.000
6.500
5.375
3.500
Adjustable mounting brackets
OCH46 = 48.0
OCH57 = 59.0
OCH46 = 47.0
OCH57 = 58.0
Figure 1: End View
Figure 2: Side View
10-32 Nylon
Lock Nut
Mounting
Bracket
10-32 x ½”
Screws
Figure 3: Mounting View
Figure 4: Mounting View