TPI Corporation FES-4548-3 Installation Instructions Download Page 3

ECO 1-7575   

REV. LEVEL: D  

REV. DATE: 10-25-2019  

FORM:8992 

 

3 OF 5

FES-4557-3

FES-6048-3

WIRING DIAGRAMS

FAN

HEAT

FAN

DELAY

OFF

3

1

H

H

TRANSFORMER  -------------------- XFMR

CONTROL TERMINAL BLOCK  ---- CTB

HTCO (Limit Control)  ---------------

HEATING ELEMENT  --------------------- E

BLOWER MOTOR ------------------------- B

CONTROLLING CONTACTOR  ----- CC

FACTORY WIRING

WIRING DIAGRAM LEGEND

THERMOSTAT ----------------------   STAT

BLOWER TERMINAL BLOCK  -----  BTB

LINE TERMINAL BLOCK ------------  LTB

GROUND LUG ------------------------  GND

480 VAC

ORANGE

BLACK

YELLOW

SPLICE

YELLOW

BLUE

GREEN

SPLICE

FAN

DELAY

OFF

3
1

H

H

BRN/WHT

BLACK

YELLOW

SPLICE

YELLOW

BL

UE

GREEN

FLANGED INLET RECEPT.  --------  FIR

MOTOR

CONTACTOR

SPLICE

POWER SUPPLY

BROWN

FAN

HEAT

TRANSFORMER  ------------------- XFMR

CONTROL TERMINAL BLOCK  --- CTB

HTCO (Limit Control)  ---------------

HEATING ELEMENT  -------------------- E

BLOWER MOTOR ------------------------ B

CONTROLLING CONTACTOR  ---- CC

FACTORY WIRING

FIELD WIRING

WIRING DIAGRAM LEGEND

THERMOSTAT ---------------------   STAT

LINE TERMINAL BLOCK -----------  LTB

DISCONNECT SWITCH  -------------  DS

GROUND LUG -----------------------  GND

Summary of Contents for FES-4548-3

Page 1: ...53 585 BTU FES 6048 3 04915302 60 480 3 73 5 2500 CFM 204 780 BTU FES 6057 3 04915402 60 575 3 61 3 2500 CFM 204 780 BTU Description Fostoria portable electric salamander heaters provide clean odor free fan forced heat They are designed to circulate room air continously gradually heating a confined space The best results will be obtained when using these heaters in smaller insulated spaces Feature...

Page 2: ...er to these heaters MUST have a ground bus or ground pole that is securely bonded to earth ground Connect green ground conductor on feeder cable or cable kit to grounding lug on heaters Comply with ALL local electrical codes and the National Electric Code NFPA70 when providing electrical power to these heaters FES 4548 3 WIRING DIAGRAMS LTB GRD E E E E E E E E CC2 ELEMENTS WIRED WYE CAPACITOR POWE...

Page 3: ...R TERMINAL BLOCK BTB LINE TERMINAL BLOCK LTB GROUND LUG GND 480 VAC ORANGE BLACK YELLOW SPLICE YELLOW BLUE GREEN SPLICE FAN DELAY OFF 3 1 H H BRN WHT BLACK YELLOW SPLICE YELLOW BLUE GREEN FLANGED INLET RECEPT FIR MOTOR CONTACTOR SPLICE POWER SUPPLY BROWN FAN HEAT TRANSFORMER XFMR CONTROL TERMINAL BLOCK CTB HTCO Limit Control HEATING ELEMENT E BLOWER MOTOR B CONTROLLING CONTACTOR CC FACTORY WIRING ...

Page 4: ... WHT BLACK WHITE YELLOW BLUE TRANSFORMER XFMR CONTROL TERMINAL BLOCK CTB HTCO Limit Control HEATING ELEMENT E BLOWER MOTOR B CONTROLLING CONTACTOR CC FACTORY WIRING WIRING DIAGRAM LEGEND THERMOSTAT STAT BLOWER TERMINAL BLOCK BTB LINE TERMINAL BLOCK LTB GROUND LUG GND FUSES CC1 E E E E E E E E E E E ELEMENTS WIRED WYE CONTACTOR COILS CC2 CAPACITOR XFMR FUSES GND BLOWER MOTOR STAT HTCO CC2 ...

Page 5: ...o fan only function as the thermostat is always calling for heat Setting the thermostat to high heat versus low heat does not make the unit operate at a higher temperature It simply raises the temperature necessary to satisfy the thermostat The unit will run longer to try to satisfy a higher thermostat setting Note ALL FES models are equipped with an internal over temperature limit designed to pro...

Reviews: