TPI Corporation 3200 Series Manual Download Page 6

REV. LEVEL: A   

ECO 1-7565   

REV. DATE: 9-2019 

 

FORM:8979 

 

1 OF 4

INSTALLATION AND OPERATION 

INSTRUCTIONS

3200 SERIES

INSTALLATION

 

INSTRUCTIONS

 

SAVE THESE INSTRUCTIONS

Caution: 

To prevent electric shock disconnect power to heater at main service before wiring or service.

Attention:

 pour éviter tout risque d’électrocution, déconnectez l’alimentation de l’appareil de chauffage lors de l’entretien 

principal avant le câblage ou l’entretien.

Caution: 

Do not obstruct the front of the heater with curtains, furniture, doors, etc. Do not place heaters under towel racks. 

Proper operation of the heater requires a free flow intake and exhaust of air.

Attention:

 Ne bloquez pas l’avant du radiateur avec des rideaux, des meubles, des portes, etc. Ne placez pas de radiateur 

sous le porte-serviettes. Le bon fonctionnement de l’appareil de chauffage nécessite une entrée et une sortie d’air libres.

GENERAL

These heaters are designed for 2 X 4 recessed or surface mount installation.  The 3200 series heaters may be wall mounted 

in a vertical position with top discharge, or horizontal position with right or left discharge. The minimum clearance for the 

3200 series is 12 inches to  the adjacent wall and 6 inches minimum from the floor. These heaters must not be installed 

without wallbox model no. BOX 30WB.

INSTALLATION OF WALL BOX 30WB

FOR NEW CONSTRUCTION

1. 

Position the wall box, maintaining minimum clearances as stated above. Secure to wall stud with nails or screws.  Wall 

box

2. 

Must be installed with front edge flush with finished wall surface.  See figure 1. Remove knockout in wall box for power 

source, and install cable clamp.

3. 

Insert supply cable through clamp allowing 6-8” for field wiring.

NOTE: 

Field wiring must enter the wall box on the left side of the  fan end of the heater. 

TPI Corporation 114 Roscoe Fitz Road, Gray TN 37615,  www.tpicorp.com

Summary of Contents for 3200 Series

Page 1: ...vides authorization for ETL Markings a Details this product is ETL Intertek Listed for U S A and Canada 2 Instruction Manual a Information that is included with the product TPI Corporation established in 1949 is the parent company of Markel Raywall Fostoria TPI Industrial HotPod and Columbus Electric TPI Corporation located in Tennessee 114 Roscoe Fitz Road Gray TN 37615 manufactures electric heat...

Page 2: ......

Page 3: ...el Nos HLA PHLA followed by 12 16 20 followed by 208 240 480 600 followed by 1 3 followed by 60 followed by 3 5 7 5 10 15 20 25 followed by 24 120 208 240 may be followed by T Air Heaters Model Nos MDC121005 MDC281005 MDC271005 MDC241005 MDC341005 MDC481005 MDC601005 E8801005 F8801005 G8801005 H8801005 L8801005 P8801005 U8801005 Air Curtain with Electric Air Heater Model Nos CFHTR36 CFHTR48 CFHTR6...

Page 4: ...CH 81SCH followed by 1 2 3 4 5 Model Nos 23SCH 83SCH followed by 4 5 Model Nos 41SCH followed by 2 3 4 5 Model Nos 43SCH followed by 4 5 Electric Air Heater Model No CFHTR followed by 36 48 60 followed by 03 05 7 5 10 12 15 followed by 208 240 277 480 followed by 1 or 3 Heavy duty Flat Panel Emitter Electric Overhead Infrared Heaters Model Nos FSS followed by 1412 1420 1424 1427 1448 1457 3120 312...

Page 5: ... be followed by up to five additional characters F32 or H32 followed by THA or THSS followed by 30 or 60 Wall Mounted Air Heaters Model Nos E followed by 32 followed by 75 10 or 15 may be followed by T or T2 F followed by 32 followed by 75 10 15 20 or 22 may be followed by T or T2 H followed by 32 followed by 75 10 15 20 or 22 may be followed by T or T2 HF followed by 32 followed by 10 15 20 or 22...

Page 6: ... chauffage nécessite une entrée et une sortie d air libres GENERAL These heaters are designed for 2 X 4 recessed or surface mount installation The 3200 series heaters may be wall mounted in a vertical position with top discharge or horizontal position with right or left discharge The minimum clearance for the 3200 series is 12 inches to the adjacent wall and 6 inches minimum from the floor These h...

Page 7: ...internal disconnect switch if provided 8 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric chock or fire or damage the heater 9 To prevent a possible fire do not block air intakes or exhaust in any manner 10 A heater has hot and arcing or sparking parts inside WARNING Do not use it in area where gasoline paint or flammable liquids are ...

Page 8: ...wire nuts or crimp terminals INSTALLATION OF GRILLE AND KNOB 1 Place the two no 8 oval head screws into grille mounting holes 2 Align grille with heater and secure Be careful not to over tighten 3 To install knob align flat of thermostat shaft with flat on knob Push knob onto shaft until knob almost touches grille 4 For tamper resistant installation set thermostat with knob remove knob and replace...

Page 9: ...REV LEVEL A ECO 1 7565 REV DATE 9 2019 FORM 8979 4 OF 4 WIRING SCHEMATICS THERMOSTAT L2 ELEMENT DOUBLE POLE MOTOR L1 SINGLE POLE L1 L2 N THERMOSTAT ELEMENT MOTOR ...

Reviews: