tozen Y-STRAINER Installation, Operation And Maintenance Manual Download Page 2

1

Verify carefully in order to ensure that the usage of strainer matches with its performance specification. 

2

Have to clear up inner parts of the strainer.

The strainer is applied by one direction and the flow direction of medium is founded by arrowhead on body.   

Please pay attention to when you set up it.

The  position  of  installation  should  make  sure  convenience  of  usage  and maintenance. 

Bolts  connected  with  flanges  must  be screwed  proportionally  when  strainer  is connected in pipe.   

For strainer of big size and heavy weight, support is needed in order to minish load for avoiding pipe’s bend.  

On the process of the usage of strainer, workers should check periodically and clear up timely sundries and 

dirty substances in screen for avoiding its damage.

1

Possible trouble, cause and removing method  

Possible trouble   

Cause

Removing method 

Leak  in  body  and cover 

1.  Bolts connected flanges are not tightened

tightened or not screwed evenly  

2. Sealing gasket is damaged

1. Screwing the bolts tightly 

2. Change sealing gasket 

Leak by the connection 

between strainer and pipe  

Bolts used for connection is not screwed  

evenly and tightly, gasket between  

strainers and flanges is aging 

Screwing the bolts evenly and   

tightly, change gasket between 

strainers and flanges 

Not good quality 

Screen is damaged 

Change screen 

Y-0121