10
4
I
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
1
Let the heater cool down.
2
Remove the removable tank
from the heater and remove the fuel
acceptance fitting (Fig. P). Some drops may leak from the fuel acceptance
fitting; keep a cloth at hand. Store the fuel acceptance fitting and the
removable tank outside the heater.
3
Place the transportation cap into the position of the fuel acceptance fitting
(Fig. Q). Press it tight.
4
Always move the heater in an upright position.
J
SPECIFICATIONS
Ignition
electrical
Dimensions (mm)
width
422
Fuel
paraffin
(including base plate) depth
281
Capacity (kW)
1.87-2.20
height
446
Suitable space (m
3
)**
35-80
Accessories: manual fuel pump
transportation cap
Fuel consumption (l/hr) 0.195-0.229
Required batteries
4x LR20, MIN 1300
Fuel consumption (g/hr)
156-183
1.5V, size D
Burning time per tank (hr) 17.5-20.5
Wick type
F
Capacity removable tank (litres) 4.0
Weight (kg)
7.5
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
2
level (NDIR CO
2
sensor
).
** Specified values are indicative