7. OPERATION
CONTROL PANEL
After turning the air conditioner off, you must wait 3 minutes before switching it back on again.
Power Control
The power button turns the unit on and off.
Fahrenheit/Celsius Selector
Press F/C toggle button to ˚F or ˚C setting.
Note: Initial setting is ˚F.
Mode Control
The Mode control has 4 settings:
Cool Dehumidify
Fan
Auto
The settings are adjusted by Mode button.
• Cooling Mode
During the cooling mode the air is cooled and hot
air is exhausted to the outside air through the
exhaust tube. Adjust fan speed and temperature
to suit your desired comfort level.
Note: Both of the exhaust duct hoses must vent
outside the room when using Cool Mode.
• Dehumidify Mode
Air is dehumidified as it passes through air condi-
tioner, without being in full cooling mode.
The fan will operate in med speed. Fan speed is
not adjustable in dehumidify mode.
Note: The exhaust duct hose must vent inside the
room when using Dehumidify Mode, not outside
as it does when cooling.
If the unit is vented outside some cooling will
occur.
• Fan Mode
Air is circulated throughout the room without
cooling.
Note: Unit does not need to be vented in Fan
Mode.
• Auto Mode
To turn on the unit chooses "Auto" mode. The unit
will switch its mode and fan speed automatically
base on the environment temperature.
Fan Speed Control
The Fan Speed Control has 4 settings: Auto, High,
Medium, and Low.
Temp Set Controls
Press "
" or "
" to set temperature. The setting
range is from 64˚F (18˚C) to 90˚F (32˚C).
Note: When choose AUTO, DEHUMIDIFY or FAN
MODE, temperature setting button invalid.
Clock Set Controls
• Press CLOCK button, LCD clock display flashes.
Press "
" or "
". In every holding second, LCD
clock display changes setting by 1 min. interval.
• Press "
" or "
" and holding mode than 1 sec-
ond, the LCD clock display changes setting with-
out interval.
• When complete setting, press CLOCK button
again to confirm the setting. LCD CLOCK display
stops flashing.
Timer Set Controls
• When unit is running and press TIMER button,
TIMER will be "off" .
• When unit is stand-by and press TIMER button,
TIMER will be "on".
• To cancel TIMER "off" or TIMER "on", simply
press POWER ON/OFF button.
• "00" = No timer setting.
• Timer setting range is 1 ~ 12 hours.
Note:
If there is no response, when press remote control,
please check battery installation properly or out of
erectricity. If it's ok, Please:
Press and hold the emergency ON/OFF switch on the
unit. Continue to hold the emergency ON/OFF switch and
press the power button on the remote control after 5 sec-
onds there will be a beep. You will hear another beep.
Release both the emergency ON/OFF switch and the
power button. Your remote control is now ready for use.
Symbols:
Cooling mode
High speed
Dehumidify mode
Fan only mode
Medium speed
Low speed
FAN
SPEED
POWER
ON/OFF
MODE
DOWN
UP
FAHRENHEIT/
CELSIUS
SELECTOR
TIMER
CLOCK
LCD DISPLAY
Launch signal indicator
TIMER ON/OFF
FAN SPEED
indicator
MODE
indicator
TIMER setting
indicator
CLOCK indicator
˚F/˚C indicator
SETTING TEMPERATURE
indicator