![Toyotomi MTN-MTG A128FS Service Manual Download Page 32](http://html1.mh-extra.com/html/toyotomi/mtn-mtg-a128fs/mtn-mtg-a128fs_service-manual_1143331032.webp)
42
8.4.3.5 Defrosting mode
:
For 9k,12k models:
z
Condition of defrosting:
AC will enter defrosting mode if any of the following items is satisfied.
(1) Both A and B are satisfied
A: The compressor keeps running for 40 minutes.
B: The evaporator coil temp.T2-Indoor room temp.T1 meets the below table.
T2
-
T1
High speed
<
TH
DEFROST
Medium speed
<
TM
DEFROST
Low speed
<
TL
DEFROST
Breeze/off
No need to compare the T2 and T1
model TH
DEFROST
TM
DEFROST
TM
DEFROST
MTN A128FS
14 15 16
MTN A135FS
14 15 16
(2) After the last defrosting, the time that the outdoor fan is off but the compressor is on in high T2
protection cumulates up to 90 minutes.
z
Condition of ending defrosting:
If any one of the following items is satisfied, the defrosting will terminate and the machine will turn to
normal heating mode.