Toyotomi LC-33 Instruction Manual Download Page 8

6

TIMER IGNITION

Your heater can be arranged to ignite automatcally at a chosen time by use of a pre-set 

“Timer”. This “Timer” can only be set after the clock setting has been completed.

1.  Press the       button and then the “Timer” key immediately 

after that. The Timer Lamp and Digital Indicator will start 

blinking.

2.  To  set the “Timer” to the chosen igntion time, you should 

follow the same procedure as given earlier for “Clock” time 

setting. After approximately 10 seconds, the digital indicator 

will return to “Clock” mode, displaying the present time.

3.  Your heater will now automatically start up the pre-set time.

4.  If you wish to start up the heater at the pre-set time again, repeat the same 

procedure 1. mentioned above.

NOTE: The pre-set time will remain so long as the heater receives electrical power. 

In the event of power failure or disconnection of heater, timer setting will be 

cancelled.

NOTE:  If normal ignition was used to set the heater burning (i.e. the heater is 

burning but the Timer Lamp on the Indicator panel is out), pressing the Timer 

key will extinguish the heater, and the heater will be put into the “Timer” 

mode.

TEMPERATURE REGULATION

1. Use the adjustment keys (

▼ 

hour/

  ▲ 

min.) to adjust the 

temperature.

2.  Adjust the temperature using the key on the right (

▲ 

min.) to 

set the temperature to a higher setting and the key on the left 
(

▼ 

hour) to lower the temperature.

3. Until the room temperature has reached the set temperature, the heater will burn at 

either high or medium burning mode. When the room temperature reaches or 
slightly exceeds the set temperature, the heater will automatically shift to maintain 
the desired temperature.

Summary of Contents for LC-33

Page 1: ...ENTS READ AND UNDERSTAND INSTRUCTIONS BEFORE USING HEATER RETAIN INSTRUCTIONS FOR FUTURE REFERENCE SPECIFICATIONS PART NAME OPERATION EMERGENCY MESSAGE 1 1 5 9 ROUTINE MAINTENANCE TROUBLESHOOTING LONG TERM STORAGE 10 11 12 MODEL LC 33 ...

Page 2: ......

Page 3: ...ng the area the heater must be turned off frequently or doors opened to other areas of the house or windows to the outside opened to cool the area If you use a heater too small for the area to be heated it will take much longer to reach the desired temperature in fact it may not be reached at all depending on the outside weather conditions MODEL HEAT RATING FUEL TANK CAPACITY BURNING TIME DIMENSIO...

Page 4: ...arm Oxygen level in room is insufficient Heater shuts off automatically with alarm sound Childproof Lock is on Heater in operation in timer mode The operation is in Save mode operation Operation Lamp Fuel Indicator Ventilation Indicator Key lock Indicator Timer Lamp Save Indicator flashing constant constant flashing flashing constant constant constant Adjustment Keys ON OFF Button Digital Indicato...

Page 5: ... it is not level NOTE If your heater is not on a level surface change its location Do not attempt to prop heater up with books or other objects More than 50cm More than 20cm More than 20cm WARNING This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental ca pabilities or lack of experience and knowledge if they have been given supervisio...

Page 6: ...imes Once flow begins it is no longer necessary to squeeze the bulb 4 Check the removable tank fuel gauge while filling the tank Stop filling by loosening the switch button on top of the pump turn anti clockwise once the gauge indicates that the tank is full Never overfill the tank especially not when the fuel is very cold fuel expands when it heats up NOTE Be careful to avoid overfilling the tank...

Page 7: ... and the heater will automatically switch into the stand by position IGNITION 1 Just press the button to ignite the heater Operation Lamp will start blinking indicating that the ignition procedure has started This will take a short while 2 After this time heater will automatically ignite and Operation Lamp will cease its flashing The Operation Lamp will remain alight so long as heater is burning N...

Page 8: ... NOTE The pre set time will remain so long as the heater receives electrical power In the event of power failure or disconnection of heater timer setting will be cancelled NOTE If normal ignition was used to set the heater burning i e the heater is burning but the Timer Lamp on the Indicator panel is out pressing the Timer key will extinguish the heater and the heater will be put into the Timer mo...

Page 9: ...ell by adjusting its heating capacity SAVE is an economy setting which you can use when for instance you are not present in the room or to keep it frost free CHILDPROOF LOCK The childproof lock can be used to prevent children accidentally changing the heater settings When the heater is burning and the childproof lock is on the heater can only be switched off Other functions are blocked then If the...

Page 10: ...fter the refill before the heater is completely ready for use again TURNING OFF HEATER While heater is burning press button to OFF position This will extinguish heater and Operation Lamp on the indicator panel will go out The circulation fan motor will operate further for approximately 90 seconds to assist in cooling down heater NEVER Turn heater off by disconnecting the heater plug from the main ...

Page 11: ...Contact your dealer Primary flame rod is malfunctioning and or dirty You have accidentaly activated your safety Tip over switch You should reset this device as described press the OFF button and restart your heater Burner flame has been extinguished during operation Check to see if air filter is clogged with dust If so clean air filter Room temperature above 32 C Failure of blower motor Air filter...

Page 12: ...ck of the heater 2 Clean Fuel Acceptance Fitting When dirt or dust accumulates in the fuel acceptance fitting it should be cleaned Check fuel acceptance fitting each time your refuel 3 Check for fuel leaks Make it a habit to check for signs of fuel leakage Wipe off any spilled fuel on the sub tank and removable fuel tank Spilled fuel may cause odor or risk of fire 4 Clean Louvers Dust and stains s...

Page 13: ...unction High limit switch activated Clogged air filter Loose screws or incorrect assembly Incorrect wiring Circuit board or fuel pump malfunction Altitude too high SOLUTION Plug into 230V AC outlet Consult your dealer Consult your dealer Refuel Clean air filter Remove fuel and refuel using fresh clear kerosene paraffin Consult your dealer Consult your dealer Clean air filter Wipe off any kerosene ...

Page 14: ...Clean Heater Wipe off any dirt or dust on heater with a damp cloth then wipe again using a dry cloth 3 If your heater needs any service or repair now is the time to call your dealer to have it done before storage That way it will be ready for immediate use when the next heating season begins 4 Store Heater The original shipping carton is the best place to store your heater If you do not have the o...

Page 15: ...t for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this...

Page 16: ...New 07 16 Printed in Japan 8684001921 5 17 Momozono cho Mizuho ku Nagoya Japan www toyotomi jp TOYOTOMI CO LTD ...