![Toyotomi Laser 300 Service Manual Download Page 38](http://html1.mh-extra.com/html/toyotomi/laser-300/laser-300_service-manual_1143453038.webp)
S E R V I C E
M A N U A L
36
SOLUTION
CAUSE
RESULT
CHECK5
RESULT
CHECK4
RESULT
CHECK3
RESULT
CHECK2
RESULT
CHECK1
Curtain or other obstruction covers
circulation air inlet
Remove obstacle
Obstacle covers circulating air outlet
Check and replace fan motor
Circulation fan motor malfunction
Check and correct wiring
Incorrect wiring
Check or replace main circuit board
Clean fan cover
Keep curtain from unit
Main circuit board malfunction
Check or replace main circuit board
Main circuit board malfunction
Check or replace burner thermistor
Bumer thermistor malfunction
Check and clean fuel pipe
Check blower motor
Check fuel pump
Fuel drain in bumer
Remove fuel in the burner
Heater won't re-start by the power
switch. Unplug the heater
Ignition failure occured three times
consecutively with E-2 error code
Fuel may accumulate in the bumer
Correct or replace wires
Wiring failure
Yes.
No.
Yes.
No.
Yes.
No.
Is window
curtain
too close
to the
rear of unit?
The
overheat
protector
is activated
Is circula-
tion fan
cover
dusty?
Does circu-
lation fan
operate
properly?
Resistor is
below
200k
Ω
after
preheating
Stops
operation
and
indicates
error code
“E-13”
Stops
operation
and
indicates
error code
“E-12”
Stops
operation
and
indicates
error code
“E-22”
FAILURE
5
6
7
L A S E R H E A T I N G S Y S T E M S
Trouble Shooting