![Toyotomi FF-95 Operating Manual Download Page 11](http://html1.mh-extra.com/html/toyotomi/ff-95/ff-95_operating-manual_1143437011.webp)
ENGLISH
GB
10
Louver
Integral fuel strainer (inside)
Fan cover
Fan cover
Louver
Integral fuel strainer (inside)
Check
Check
TURNING HEATER OFF
Press ON/OFF switch to “OFF” position. ON lamp will flash and will go out. Circulation fan
and blower motor continue to run for approx. three (3) minutes to cool down the heater.
NOTE: ON lamp goes out when the fan stops.
NOTE: If ON/OFF switch is pressed during the weekly timer operation mode, the weekly
timer operation mode is canceled.
SECTION F:
ROUTINE MAINTENANCE
CAUTION:
Be sure to disconnect heater before performing any checks or cleaning.
CAUTION:
Allow heater to cool completely before cleaning or maintenance.
FOR OPTIMUM HEATER PERFORMANCE, THE PARTS SHOWN BELOW SHOULD BE CLEANED REGULARLY:
1. Clean Louvers (ONCE A WEEK)
Dust and stains should be wiped off louvers with a damp cloth.
2. Clean Circulation Air Filter (ONCE A WEEK)
A mesh filter is located on heater cabinet rear side.
Once a week slide the filter up to remove and it should be vacuumed clean.
3. Check for Fuel Leaks (REGULARLY)
Make it a habit to check for any sign of fuel leakage along the fuel line and at all joints.
Fuel leaks may lead to risk of fire.
4. Check Flue Pipe Area (ONCE A WEEK)
Check the flue pipe joint to make sure connection is firm.