background image

Kerosene-Fired and Oil-Fired Water Heater

Operation and Maintenance Instructions

MODEL

BS-36UFF

(Type C)

CONTENTS

IMPORTANT

READ AND UNDERSTAND INSTRUCTIONS BEFORE INSTALLING OR USING THIS WATER HEATER.

RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.  CHECK LOCAL CODES AND ORDINANCES FOR

PERMITTED USE.

CAUTION

THIS WATER HEATER SHALL NOT BE USED FOR COMMERCIAL USE OR FOR ANY PURPOSES OTHER

THAN HOT WATER SUPPLY USES. OTHER USAGE MAY CAUSE A MALFUNCTION OR SHORTEN ITS

SERVICE LIFE. DO NOT REMOVE THE RATING PLATE AND LABELS FROM THE WATER HEATER UNIT.

SECTION A:

Safety Tips

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

1

Safety Features

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

3

SECTION B:

Specifications

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

4

Dimensional Outline

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

5

Control Panel

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

6

Construction

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

6

SECTION C:

Fuel Guide

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

7

SECTION D:

Operation

Fueling

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

8

Inspection Before Operation

⋯⋯⋯⋯⋯⋯⋯⋯

8

Operation

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

9

Adjusting Water Temperature

⋯⋯⋯⋯⋯⋯⋯

9

Flow Rate and Water Temperature

⋯⋯⋯⋯

10

Turning Unit Off

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

10

Preventing Freeze Up

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

10

Long Term Inactivity

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

11

SECTION E:

Routine Maintenance

Inspection and Maintenance

⋯⋯⋯⋯⋯⋯⋯

12

Inspection and Maintenance Items

⋯⋯⋯⋯

12

SECTION F:

Troubleshooting

⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯

13

 BS-36UFF(OP/E)  06.9.19 1:48 PM   ページ b

Summary of Contents for BS-36UFF

Page 1: ...OTHER USAGE MAY CAUSE A MALFUNCTION OR SHORTEN ITS SERVICE LIFE DO NOT REMOVE THE RATING PLATE AND LABELS FROM THE WATER HEATER UNIT SECTION A Safety Tips 1 Safety Features 3 SECTION B Specifications...

Page 2: ...nect power cord before ser vicing unit 7 This water heater is designed to be used no more than 6 890 FT 2 100 m above sea level The water heater may have a failure of combustion at a high altitude Ask...

Page 3: ...ime shut off the fuel valve on the fuel tank Press POWER SWITCH to OFF position and disconnect the power supply cord 10 If the unit is not used for a long period of time the fuel tank may contain wate...

Page 4: ...ible Link Valve If a household fire should occur causing the fuel line or water heater to become extremely hot the fusible link valve will stop the fuel supply to the burner This will prevent the fuel...

Page 5: ...h of Vent Pipe System 10 ft 3 bends or less Electrical Rating 120 Volts AC 60 Hz Ignition 120W Burning 98W Required Accessories Fuel strainer Temp pressure relief valve Safety Device Over heat protect...

Page 6: ...2 3 4 70mm Drain Outlet NPT 1 2 Male Air Intake Inlet 2 3 4 70mm Access Cover Water Supply Inlet NPT 3 4 Male Hot water Supply Outlet NPT 3 4 Male Junction Box Front Panel 5 1 8 130mm 5 1 8 130mm 3 16...

Page 7: ...Y BEFORECHANGINGTEMPERATURE SETTING SEE INSTRUCTION MANUAL BS 36U ON OFF POWER THERMOSTAT B HOT A COLD VERY HOT 130 F WARNING BURNER OPERATION Main Circuit Board Thermistor Fuel Pump Ignition Transfor...

Page 8: ...f contaminants water or cloudiness NEVER Gasoline alcohol white gas camp stove fuel or additives NEVER Yellow or sour smelling fuel How to Store It ALWAYS Store in a clean container non red in color c...

Page 9: ...spilled fuel 5 Remove the trapped air thoroughly Failure to remove all the air will cause improper ignition and may extinguish the unit 6 Tighten the screw after removing trapped air 7 Reconnect the...

Page 10: ...When using a shower feel the temperature of the water with your hand before getting under the water Risk of scald injury Before changing the temperature setting make sure that the water heater is not...

Page 11: ...NG FREEZE UP In order to prevent any kind of damage or leaks caused by freezing keep the pipes heated at all times as specified below CAUTION In order to prevent the water heater from being broken or...

Page 12: ...r starts flowing continuously NOTE Since the water heater and piping system still have much air left after they are drained a flash flow of water may be caused by such air pressure when re supplying w...

Page 13: ...fuel thoroughly when lubricating fuel If a leak is found shut down the unit until the problem is corrected 3 FUEL FEED LINE INSPECTION REGULARLY Check for fuel leaks from the fuel feed line Replace it...

Page 14: ...the beam receiving surface of the flame sensor becomes dirty or contaminated the unit will not operate properly The beam receiving surface should be wiped with a soft cloth every 6 months 15 BLOWER MO...

Page 15: ...line and pump Fuel flow too much Fuel flow too little Fuel nozzle malfunction Improper installation of flue pipe Thermistor malfunction Hot water supply beyond capacity Dusty blower motor fan Imprope...

Page 16: ...s not available locally please contact our CUSTOMER RELATIONS DEPARTMENT at TOYOTOMI U S A INC 604 Federal Road Brookfield CT 06804 203 775 1909 THE FOREGOING EXPRESSES ALL OF TOYOTOMI S OBLIGATIONS A...