Please read the instructions before installing:
•
Movement sensors should be preferably installed by a trained electrician who can understand the
installation procedure and guidelines.
•
Ensure wires are properly connected with reference to phase, neutral and load.
•
Concentrated Light from IR emitting fluorescent lamps should not fall on the sensor window, which
may disturb the sensing operations. As such ensure a minimum distance of around 3 meters between
the florescent lamp and the movement sensor.
•
Install the movement sensor only at the specified height
•
Install the movement sensor in such a way that the detection range is angled across the movement.
•
Use only transformers/Ballast made to IEC or equivalent standards by manufacturers of repute.
•
If required connect 2.2uF/440V AC Fan Capacitor across CFL with electronic ballasts to avoid blinking
in OFF state.
•
Connect upto specified wattage of load only. For higher loads suitable rated contactor of reputed make
can be used.
•
Hindrance / moving object should not hide the detection window.
•
Avoid installing in Bathrooms. Make sure air conditioners, central heating, etc.do not cloud IR window.
INSTALLATION OFMOVEMENT SENSOR– Steps:
1. Turn OFF power through the MCB.
2. Remove the top cover from the sensor by anti-clock wise turn.
3. Connect the movement sensor as per the wiring diagram shown below.
4. Mount the sensor on the selected position with the screw.
5. Place the top cover on the sensor and turn it clockwise to lock.
6. Turn ON the power through the MCB.
WIRING DIAGRAM OF MOVEMENT SENSOR:
NEUTRAL(BLUE)
PHASE(BROWN)
LOAD
TO LOAD(RED)
TO NEUTRAL
Note:
Use 0.75 Sq.mm.flexible wires for connections (Phase, neutral & load)