Maintenance
TOX_Manual_FinePress_PFHL-PFHW_en
63
10.3.2
Inspecting the fastening of the press head
1
1
Fastening screws
ü
System is in maintenance position.
See
Set system to maintenance position, Page 61
.
1.
Check the tightening torque of the fastening screws.
2.
NOTE!
Damage on the tool! Check the alignment of the tool!
Screw size
Tightening torque
M 12
135 Nm
M 16
340 Nm
Tab. 2
Fastening screws of the press head on the frame