Troubleshooting
46
TOX_Manual_ElectricPowerDrive_EQe-K_en
10.2
Searching for causes of fault
Faults are displayed and described as errors or warnings on the central
control unit depending on the type of alarms.
Faults may only eliminated by trained and authorized service personnel.
Fault
Possible cause
possible measure
The working piston does not
extend.
Power supply interrupted
Check the main switch position.
Establish power supply.
Mechanical fault
Contact authorized service personnel.
Control system fault
Faulty programming
Press force not reached.
The working piston does not
retract.
Mechanical fault
Contact authorized service personnel.
Electrical defect
Control system fault
Faulty programming
System overloaded
Check approved loads.
Contact authorized service personnel.
The device moves outside the
tolerances to the set stroke val-
ues (tolerance error).
Control system fault
Contact authorized service personnel.
Reference signal is not detected cor-
rectly
Check reference switch, cable and con-
trol system.
Contact authorized service personnel.
Device stops during the work
cycle.
Power supply interrupted
Check the main switch position. Estab-
lish power supply.
Mechanical fault
Contact authorized service personnel.
Electrical defect
Control system fault
Thermal overload of motor or controller
Allow the motor and controller to cool
down.
Program work cycle so that thermal
overload no longer occurs.
Contact authorized service personnel.
Error during the referencing.
Mechanical fault
Contamination present
Reference sensor defective
Contact authorized service personnel.
Summary of Contents for EQe-K
Page 2: ...2 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 12: ...Important information 12 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 26: ...About this product 26 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 28: ...Technical data 28 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 32: ...Transport and storage 32 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 38: ...Installation 38 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 44: ...Software 44 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 48: ...Troubleshooting 48 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 50: ...Maintenance table 50 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 58: ...Maintenance 58 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 60: ...Repairs 60 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 64: ...Appendices 64 TOX_Manual_ElectricPowerDrive_EQe K_en ...
Page 65: ......
Page 66: ......
Page 70: ...Index 70 TOX_Manual_ElectricPowerDrive_EQe K_en ...