• The unit must be installed in an area or room with suffi cient fresh air supply to ensure proper combustion.
• There must be adequate clearance for air openings into the combustion chamber.
• This equipment must be installed with adequate clearance for servicing and proper operation.
• This unit should be operated only with drip trays in place.
• Use of the supplied gas pressure regulator is mandatory.
• The front of the unit must be kept clear to avoid restriction of air supply for proper combustion.
• If your unit is supplied with casters, the installation shall be made with a connector that complies with the
standard for connectors for Movable Gas Appliances, ANSI Z21.69 or connectors for Moveable Gas
Appliances, CAN/CGA-6.16, and a Quick-Disconnect Device that complies with the standard for
Quick-Disconnect Devices for use with gas fuel ANSI Z21.41, or Quick-Disconnect Devices for use with
Gas fuel, CAN1-6.9, and adequate means must be provided to limit the movement of the appliance without
depending on connector and the Quick-Disconnect Device or its associated piping to limit the
appliance movement.
• If your unit is provided with casters on legs, the legs with locking casters must be installed in front of the unit.
An approved restraining device must be secured to the unit
’
s rear or side.
1)
BURNERS AND FAUCETS
Remove any nylon hold-downs on the faucets. The burners may also have hold-downs and may have shifted
during shipping. Remove the nylon hold-downs and center the burner in the chamber. Tighten clamps as
necessary.
2)
WATER-PRESSURE REGULATOR
This wok range has a pre plumbed water pressure regulator/ fl ow
restrictor. It is factory set for 50 PSI outlet. This is done to conserve water
and prevent water from the cooling spray bar from splashing over the
side of the range causing a “leak”. When installed, the water fl ow from
the cooling line and the faucets must be checked
for adequate fl ow. If the water pressure is low at the installation site the
regulator must be adjusted to increase the water fl ow. (Please refer to the
attached instruction sheet for information on how to adjust the regulator)
With spray bar valve on you should observe a constant fl ow of water
from spray bar that fully covers the
entire deck. This applies to all rear and front gutter units except EcoDeck
Note: if water pressure is high, the regulator may need to be adjusted to
LOWER the pressure.
3
IMPORTANT INFORMATION ABOUT WATER AND GAS SETUP
_________________________________________________________________________
_________________________________________________________________________
Clockwise more pressure
counterclockwise less pressure