background image

CAEDMON ECO DEISGN SMOKE CONTROL ISSUE No. 02    10/10/2017 

 

 

with the stove – place the black cover over the handle when opening and closing the door, 
then remove and leave near the stove. 
The appliance will give more heat output with increased air supply, so the controls can be 
adjusted to increase or decrease the burning rate of the fuel, as desired. 
To get the most efficiency from the Caedmon Eco Design stove it is necessary to build up a 
bed of red ash in the grate, 2 – 2.5 inches, but not above the lower holes in the back.    Open 
the primary air vent, the one on the bottom right hand side, for two minutes.    Then close 
this air vent. Open the bottom central lever to the left, this keeps the fire well alight with 
low emissions.    To get more efficiency this lever can be partially closed. Make sure there 
is flame in the top of the stove, this will make the logs last longer and increase the 
efficiency.   
   
This appliance is hot whilst in operation. Keep children and furniture a safe distance away. 
In the presence of children, elderly or infirm people a fireguard should be used. The 
fireguard should be manufactured in accordance with BS 8423:2002 – Fireguards for use 
with solid fuel appliances. 
 
User warning - parts become very hot while the stove is running so should not be touched 
with bare hands. The special operating tool, stove handle cover and a pair of gloves are 
provided for operation of the hot stove. 
 
The appliance is designed to operate efficiently with the fire door closed. The door 
should be kept closed at all times, except when refueling or removing ashes. 

 

STOVE HANDLE COVER 

 

There is a black stove handle included with your stove this is to be used when opening and 
closing the stove door. Place the black handle cover over the handle when opening and 
closing the stove door, then remove and leave near the stove for the next time.   

 

PLEASE NOTE THIS HANDLE IS NOT TO BE LEFT ON THE STOVE WHEN 
THE STOVE IS HOT. 

 

TO RE-FUEL THE STOVE

    Do not over fill the firebox.    Open the door to re-fuel, 

the primary air at the bottom right hand side should be in the closed position.    Slide the left 
hand lever to the right to close the external air. This stops air coming from outside and 
pushing smoke into the room. Add the fuel and leave the door ajar for a period of 2 – 3 
minutes or until the new refuel charge is well alight, close the door. Then open the left hand 
lever. Use the left hand lever to adjust to suit required heat. 

 

Refueling on to a low fire bed 

If there is insufficient burning material in the firebed to light a new fuel charge, excessive 
smoke emission can occur. Refueling must be carried out onto a sufficient quantity of 
glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there 
are too few embers in the fire bed add suitable kindling to prevent excessive smoke 

Summary of Contents for Caedmon ECO Smoke Control

Page 1: ... If there is a possibility of disturbing asbestos during the installation it is necessary to take the appropriate steps to protect the installer Fire cement is caustic and protective gloves should be worn The chimney must be swept and examined for soundness and suitability before the stove is installed Remedial action should be taken if required seeking expert advice if necessary Where the chimney...

Page 2: ... the smoke control area In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015 Similarly in Scotland appliances are exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ir...

Page 3: ...mm at the back and 400 mm at the sides must be maintained from combustible materials It is a requirement that this appliance is installed on a solid level non combustible hearth conforming to current Building Regulations The Caedmon Eco Design has been tested for hearth temperatures and the maximum temperature was 56 degrees so is also suitable for a 12mm hearth INSTALLATION A minimum flue draught...

Page 4: ...flue pipe to an existing chimney a register plate is required preferably made of metal Acollar is welded to the underside of the register plate so that the flue pipe can be placed into the spigot on top of the stove and round the outside of the collar on the register plate so forming a funnel effect In this way any moisture running down the chimney will be directed back into the stove instead of s...

Page 5: ...ess pollution The turbo burner is built in and needs no adjustment LIGHTING THE STOVE When ready to light the stove for the first time make sure that everything is removed from the ashpan and then open the lever under the door to the left this is operated by hand with a glove or by foot Then slide the air inlet on the right hand side of the stove towards the front to let air in under the grate thi...

Page 6: ...operating tool stove handle cover and a pair of gloves are provided for operation of the hot stove The appliance is designed to operate efficiently with the fire door closed The door should be kept closed at all times except when refueling or removing ashes STOVE HANDLE COVER There is a black stove handle included with your stove this is to be used when opening and closing the stove door Place the...

Page 7: ...tee Wood needs to be dry and seasoned maximum 20 moisture content Do not burn any liquid fuel Do not burn wood pellets do not burn wood chips Do not burn any rubbish on the stove CLEANING THE STOVE AND FLUE It is important to remove the ashes regularly if the ash builds up through the grate the grate could overheat and distort Open the fire door with the stove glove provided and using the tool gen...

Page 8: ...ates and the chimney are swept prior to lighting up after a prolonged shutdown period TROUBLE SHOOTING 1 The stove is not burning well The stove may need more fuel loading load more fuel see lighting the stove The wood may be un seasoned or damp avoid using unsuitable wood The chimney may need sweeping or there may be a build up of debris above the baffle see Cleaning the Stove and Flue There may ...

Page 9: ...MAKE SURE THERE IS NOTHING COMBUSTIBLE NEAR THE STOVE MOVE PEOPLE AWAY FROM THE ROOM CLOSE THE ROOM DOOR PHONE THE FIRE BRIGADE COMMISSIONING AND HAND OVER INSTRUCTIONS Ensure all parts are fitted in accordance with the instructions On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out before lighting the stove Once the stove is under fire chec...

Page 10: ...n EU 2015 1187 Energy Labelling of Local Space Heaters Supplier s Name or Trademark Town Country Fires Suppliers Model Identifier Caedmon Eco Design SC Energy Efficiency Class of Model A Nominal Heat Output to Room kW 7 0 Nominal Heat Output to Water kW n a Net Efficiency 76 0 Energy Efficiency Index 100 ...

Page 11: ...ur Installation User Instructions provided with the stove Any warranty claim requires Proof of defective workmanship and delivery of the defective product to our factory within twelve months of the date of purchase Parts which are classed as consumables and are excluded from our Guarantee include Grates Fire Bricks Baffles Fuel Guards Ash Pan Glass Door Glass Seals and Paint Claims under this guar...

Page 12: ...bricks out see picture below The second side brick can now easily be removed Repeat to remove the other side brick Remove top baffle Loosen dome nut on the tertiary air control at the left hand side of the stove body remove the top rear brick Then the remaining rear bricks and air tube can be removed through the front of the stove Please note the correct position for the first baffle is with the n...

Page 13: ...elope to Town and Country Fires Ltd Unit 1 Enterprise Way Thornton Road Ind Estate Pickering North Yorkshire YO18 7NA Model Serial No CAESCED Date of Purchase Title Surname Address Date of Installation Installers Name HETAS Reg No Address Tel No Supplier Details Name Address Tel No Thank you for your co operation if you do not wish to be contacted by Town and Country Fires in the future please tic...

Reviews: