CAEDMON ECO DEISGN SMOKE CONTROL ISSUE No. 02 10/10/2017
6
with the stove – place the black cover over the handle when opening and closing the door,
then remove and leave near the stove.
The appliance will give more heat output with increased air supply, so the controls can be
adjusted to increase or decrease the burning rate of the fuel, as desired.
To get the most efficiency from the Caedmon Eco Design stove it is necessary to build up a
bed of red ash in the grate, 2 – 2.5 inches, but not above the lower holes in the back. Open
the primary air vent, the one on the bottom right hand side, for two minutes. Then close
this air vent. Open the bottom central lever to the left, this keeps the fire well alight with
low emissions. To get more efficiency this lever can be partially closed. Make sure there
is flame in the top of the stove, this will make the logs last longer and increase the
efficiency.
This appliance is hot whilst in operation. Keep children and furniture a safe distance away.
In the presence of children, elderly or infirm people a fireguard should be used. The
fireguard should be manufactured in accordance with BS 8423:2002 – Fireguards for use
with solid fuel appliances.
User warning - parts become very hot while the stove is running so should not be touched
with bare hands. The special operating tool, stove handle cover and a pair of gloves are
provided for operation of the hot stove.
The appliance is designed to operate efficiently with the fire door closed. The door
should be kept closed at all times, except when refueling or removing ashes.
STOVE HANDLE COVER
There is a black stove handle included with your stove this is to be used when opening and
closing the stove door. Place the black handle cover over the handle when opening and
closing the stove door, then remove and leave near the stove for the next time.
PLEASE NOTE THIS HANDLE IS NOT TO BE LEFT ON THE STOVE WHEN
THE STOVE IS HOT.
TO RE-FUEL THE STOVE
Do not over fill the firebox. Open the door to re-fuel,
the primary air at the bottom right hand side should be in the closed position. Slide the left
hand lever to the right to close the external air. This stops air coming from outside and
pushing smoke into the room. Add the fuel and leave the door ajar for a period of 2 – 3
minutes or until the new refuel charge is well alight, close the door. Then open the left hand
lever. Use the left hand lever to adjust to suit required heat.
Refueling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive
smoke emission can occur. Refueling must be carried out onto a sufficient quantity of
glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there
are too few embers in the fire bed add suitable kindling to prevent excessive smoke