Town & Country Fireplaces TCWS.54NG03C2 Instruction Manual Download Page 3

TCWS.54NG03C2 230911-12

If converting to propane see 
conversion instructions on page #5 
before proceeding.

Install panels according to the 
TCWS.54CE2 Installation and  
Operating manual prior to burner 
installation. (Page 23)

1.  

Install the right burner by laying into 
location trough and sliding to the right  
to engage the venturi tube over the 
orifi ce. Repeat with left burner. (Fig. 
#1)

NOTE: check air shutter for correct fuel 
setting before proceeding further. Both 
burner shutters are to be set the same, 
fully closed for natural gas. 13/64 (0.2)” 
open for LP.

CAUTION: The burners should be tightly 
butted up against each other at the center 
to ensure correct operation.

2.  

Tilt the burner tray into the unit and place 
on top of the manifold brackets(Fig.#2). 
Attach pilot to burner tray. Be sure pilot 
is attached to burner support rail with 
screw in

 fi rst hole 

position.

 (Fig. 

#2a)

3.  

Secure the burner tray to manifold 
 brackets using eight screws(Fig. #3).

Black Diamond Burner Installation

FIRST HOLE POSITION

Fig #2

Fig #3

Fig #1

Fig #2a

3

Summary of Contents for TCWS.54NG03C2

Page 1: ...ies C2 These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER ...

Page 2: ...structions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply safety requirements and operating instructions IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER 1 BURNER TRAY 2 5 LB GLASS MEDIA 2 BURNER ASSEMBLIES 1 INSTRUCTION PACK 2 ...

Page 3: ...er for correct fuel setting before proceeding further Both burner shutters are to be set the same fully closed for natural gas 13 64 0 2 open for LP CAUTION The burners should be tightly buttedupagainsteachotheratthecenter to ensure correct operation 2 Tilttheburnertrayintotheunitandplace on top of the manifold brackets Fig 2 Attach pilot to burner tray Be sure pilot is attached to burner support ...

Page 4: ...orcelain trim wide edge against the back panel and press down over the pre bent tabs on the burner tray Fig 5 6 Place the front porcelain trim so that it rests on the front shelf of the firebox and is snug against the firebox frame Ensure that the wide edge of the trim is against the firebox frame Fig 6 7 WIDE EDGE TO FRONT OF FIREPLACE WITH FRONT TRIM TO THE REAR OF THE FIREBOX FOR REAR TRIM Fig ...

Page 5: ... from the manifold brackets Fig 8b 3 Remove burners 4 Using a 1 2 wrench undo the natural gas burner orifice marked 764 Apply a small amount of pipe joint compound to the threads of the propane burner orifice marked 165 to ensure a good seal before screwing it into the fitting Loosentheprimaryairshutterscrew open shutter to give a gap of 13 64 0 2 and re tighten Repeatonother burner Fig 10 5 With ...

Page 6: ...ve Fig 15 The minimum rate screw is sealed with an O ring Use a thin bladed screwdriver to back the screw out past the limit of the threading At this point a groove on the screw body will be visible just above the valve body Insert a thin tool knife blade or fine screwdriver blade into the groove and gently pry the screw up It helps to rotate the screw while lifting on it 10 Replacetheminimumrates...

Page 7: ...m cap from the top of the pressure regulator Fig 17 12 Pressdownonthecenterpostandrotate 90 The center post should stay down Fig 19 Replace the aluminum cap 13 Fill in the date and the name of the personwhoperformedtheconversionin the white area on the conversion label Fig 18 Peelofftheprotectivebacking and apply the conversion label directly over the gas specifications on the rating label 14 Re l...

Page 8: ...lant will be required to ensure a gas tight connection Note To test the gas pressure turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port Verify gas pressures with the fireplace lit and on the highest setting SUPPLY PRESSURE MANIFOLD PRESSURE Fig 22 Correct gas pressure requirement Supply Pressure Natural Gas Propane Min Pressure 5 0 WC...

Page 9: ...ached operating temperature See Fig 25 for proper flame pattern Open primary air if the window glass and firebox have carbon accumulation and or the flames are long dark and stringy The shutter may also be opened to lessen the flame height NOTE Proper air shutter setting is required The flame should be just orange and lazy It should NEVER be set to create sooting on internal parts and window glass...

Page 10: ... TCWS 54NG03C2 230911 12 ITEM DESCRIPTION PART NO 1 BLACK DIAMOND BURNER TCWS 54NG03C2 2 GLASS MEDIA 2 required TCRP 501201 WHEN ORDERING INCLUDE PART NUMBER WITH DESCRIPTION Replacement Parts 1 KIT CONTENTS 10 ...

Page 11: ...TCWS 54NG03C2 230911 12 11 ...

Page 12: ...Technical support 1 250 748 1184 Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada ...

Reviews: