TC36STD2
Transformer
Vacuum
switch
Inside access
panel
Gas
connector
Wall switch
connector
Junction box
Module
Interface board
Power vent
switch
Regulator
board
Figure 24:
Valve assembly
components.
15
100000438-50 091418-41
Figure 22: Access to firebox.
The gas control system is located on the right hand side of the firebox behind
an access panel and the decorative firebox panel (if installed). The fireplace is
operated via a wall control and a hand held remote control unit.
The wall control is connected to the fireplace by a 40 ft. communication cable
supplied with the fireplace.
Installation
1. Place the fireplace in the desired location.
2. Remove the window from the fireplace.
3. Remove access panel from right hand side of the firebox (Figure 22).
4. Connect 110 V. AC electrical supply to the wires installed inside the
junction box (Figure 23). The fireplace is rated at 110 volts, 60Hz, 0.25A.
The optional power vent kit is rated at 115 volts, 60Hz, 1.8A.
5. The electrical wires can be accessed from both inside and outside the
junction box by removing one of the two small access panels (Figure 23
and Figure 24)
6. Attach the wall switch to the framing in the desired location (40 ft is
supplied with fireplace).
7. Route the wall switch control cable (supplied) as required to the wall
switch.
8. Attach one end of the wall switch control cable to the wall control
(Figure 26), and the other end to the interface board (Figure 24).
9. Insert the 4 supplied “AA” batteries
into the battery pack of the wall
switch (Figure 27)
10. If not already installed, install
the burner using the instructions
supplied with the burner kit.
11. Turn on the gas supply and check
that all connections are tight and
leak free.
12. Turn on gas and electrical supplies.
13. Move the center button on the wall
control to the “ON” position. The
igniter will start to spark. After
a short delay, the pilot will light
followed by the main burner.
FIREBOX ACCESS PANEL
Electrical
To Power
Vent - Blue
2 Nuetral
wires - White
Power In
wire - Black
Figure 23: Junction box wiring.