Installers Information
CAUTION:
Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing
appliance. It is recommended that the fire feature and its venting be inspected at least once a year by a
qualified service person.
Glass Panel:
Warning: Do not operate fire feature with glass panel removed, cracked or broken. Replacement of the
glass panel should be done by a licensed or qualified service person.
Do not strike or otherwise impact the glass in anyway that may cause it to break. If the glass becomes
cracked or broken it must be replaced before using the fire feature. Replacement glass can be obtained from
your nearest Town & Country Fireplaces
TM
dealer. Refer to “Door Frame Removal/Installation” on page 7
for instructions.
Annual Inspection:
a) Remove glass panel and inspect the Burner and Igniter for soot build up. If excessive build up of soot is
present, have a qualified service person inspect and adjust the unit for proper combustion.
b) Check that the venting pipe and venting terminal are open and free from blockage or debris. If the venting
is disassembled for cleaning, it must be properly assembled and re-sealed.
c) Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good
condition.
Note:
The appliance area must be kept clear and free from combustible materials, gasoline and other
flammable vapours and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with fireplace glass cleaner.
b) Exterior finish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the fire feature.
Do not clean glass when hot.
Maintenance
31
5055.64-A
TCHF.22bodyA_ 090617-36