![Town & Country Fireplaces D2 Series Installation Manual Download Page 37](http://html.mh-extra.com/html/town-and-country-fireplaces/d2-series/d2-series_installation-manual_1141169037.webp)
Annual Inspection:
1. Remove glass panel and inspect the decorative burner media (such as logs, pebbles, glass etc)
for soot build up. If excessive build up of soot is present, have a qualified service person inspect
and adjust the unit for proper combustion. Clean the decorative media and use a brush or vac-
uum cleaner to clean the burner, paying close attention to the burner ports.
2. Check the pilot system for proper flame size and operation. Clean pilot free of soot, dust or any
other deposits.
3. Check that the vent pipe and vent terminal are open and free from blockage or debris. If the
venting is disassembled for cleaning, it must be properly assembled and re-sealed. Refer to See
“Vent Pipe Sealant” on page 27 for proper procedure.
4. Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained
in good condition.
5. Check and replace batteries as needed.
Note: The appliance area must be kept clear and free from combustible materials, gasoline
and other flammable vapours and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with fireplace glass cleaner.
b) Exterior finish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other part of the fireplace.
Do not clean glass when hot.
37
100000364-50
TC42D2 091418-44