241120-16
100004780-50
8
Electrical Connection
Note:
Ensure that the power is disconnected at its
source before proceeding.
The fan unit operates using 120VAC supplied from the
fireplace and a 24VAC control signal from the fireplace
as well. Once the fan unit is secured to its frame, the
power line and control wires can be brought in from
the rear of the unit. Be sure that the plastic grommet
is installed in the hole where the power line is coming
through (Figure 7).
NOTE: The installer must supply;
• approved 14ga. household wire from the fireplace to the Power Vent, for the
120VAC power. and,
• minimum 18ga, 2 conductor (bell/alarm) wire from the fireplace to the power
vent for the 24VAC blower control.
See the fireplace manual for connections at the fireplace.
Strip the Control wires and connect
using wire nuts,
make sure that the
colour pairing matches that at
the fireplace as well.
i.e. black to
grey at both ends or red to red at both
ends.
Figure 7: Feeding wires.
Strip the Power wires and using wire
nuts secure them to the power wires
from the fireplace. Connect White
to White and Black to black and the
ground to green(Figure 8).
24 V Blower Control
from Fireplace ( Wire
not provided with
unit)
White
Black
Red
Grey
Ground
120V Power from
Fireplace ( Wire not
provided with unit)
Figure 8: FMPV Wiring Diagram.