- 88 -
4. Software Status Setting Commands
When the system is powered on, the VFD will read the DIP switches to set the
Command
Type
,
Baud Rate
,
Parity
, and
International Character set
. The user can change the
settings as follows:
1.6. Baud Rate Setting Command
STX 05 B n
ETX
/Change the baud rate setting/
ASCII Format
STX 05 B
n
ETX
Dec. Format
[02] [05] [66]
n
[03]
Hex. Format
[02h][05h][42h]
n
[
0
3
h
]
30h
≦
n
≦
33h
Description
Change the display communication baud rate. The
baud rate setting can be selected from 4800 to
38400.
n
Baud rate
30h
4800
31h
9600
32h
19200
33h
38400
1.7. Parity Check Setting Command
STX 05 P n ETX
/Change the Parity check setting/
ASCII Format
STX 05 P
n
ETX
Dec. Format
[02] [05] [80]
n
[
0
3
]
Hex. Format
[02h][05h][50h]
n
[
0
3
h
]
n
=30h, 31h
Description
Change the display communication parity. Set 8
data bit and the parity set for even or non-parity.
n
Parity
check
30h
None-parity
31h
Even-parity
Summary of Contents for Breeze All-in-one
Page 1: ...Version 3 0 March 2017 Breeze All in one User Manual...
Page 16: ...9 3 System Dimensions 3 1 15 System Dimensions...
Page 17: ...10 3 2 17 System Dimensions...
Page 47: ...40 7 Jumper Setting 7 1 B78 Motherboard 7 1 1 Motherboard Layout...
Page 53: ...46 7 2 B68 Motherboard 7 2 1 Motherboard Layout...
Page 59: ...52 7 3 B98 Motherboard 7 3 1 Motherboard layout...
Page 65: ...58 7 4 C48 Motherboard 7 4 1 C48 Motherboard Layout...
Page 66: ...59...
Page 74: ...67 7 5 C58 Motherboard 7 5 1 Motherboard Layout...
Page 78: ...71 7 6 C78 Motherboard 7 6 1 Motherboard Layout...
Page 82: ...75 7 7 Skylake Motherboard 7 7 1 Motherboard Layout...