18
19
♣
Important!
When using a printer power supply other than optional AC adaptor, be sure that the following
cautions are observed.
Use a power supply (Limited Power Supply) of DC 24V±10% and more than 1.75A.
Be careful about installing the printer in an area where there is noise.
Take the appropriate measure to protect against electrostatic AC line noise, etc.
8-5. Environmental Requirements
(1) Operating
Temperature
5°C to 40°C
Humidity
10% to 90% RH (without condensation)
(2) Transport/Storage (except paper)
Temperature
-20°C to 60°C
Humidity
10% to 90% RH (without condensation)
8-6. Reliability
(1) MCBF
60 million lines (based on an average printing rate of 12.5% with paper
thickness in the range 65µm to 75µm)
35 million lines (based on an average printing rate of 12.5% with paper
thickness in the range 76µm to 150µm)
(2) Head Life
160Km
(3) Cutter Life
1,500,000 cuts
8-7. Certification
(1)FCC PART15 CLASS A
(2)CE EMCD/LVD
(CE-EMCD class B should use parallel shield cable complied with IEEE-1284 standards)
(3) UL/cUL (UL 60950-1)
(4) KC
(5) ENERGY STAR
This equi pment is indoor use and all the communication wiring are limited to inside
of the building”
8-2. Auto Cutter Specifications
(1) Cutting Frequency
Max. 30 cuts per minute
(2) Thickness of paper
0.06 ~ 0.09 mm
(3) Cutter Life
1.5 million cuttings
8-3. Interface
RS232 Serial Interface, Centronics Parallel Interface(IEEE1284), USB Interface,
Ethernet Interface(100Mbps)
8-4. Electrical Characteristics
(1) Input Voltage
DC 24V ± 10%
(2) Current Consumption
Operating: Approx. 1.5 A (at ASC
∥
printing)
Peak : Approx. 10 A
(at print duty 100%, For 10 seconds or less)
Stand-by : Approx. 0.03 A
(3) Power Connector
♣
Preventing Overheating
To prevent the motor from overheating, continuous operation of the printer should be
1.5 m or less in print length. Set the pause time for 30 seconds or more than it.