Wipe with a cloth dampened with appropriately-diluted neutral detergent,
and then wipe with a cloth dampened with water. After that, wipe off moisture
clean with a dry cloth.
★
To customer
Please contact the sales shop for replacement parts and warranty.
Preparation for Installation
Mounting Method
■
Make sure that you have the following parts:
3
Normal cleaning
●
After wetting a cloth with water or lukewarm water, wring it out thoroughly
and then use it to wipe the product.
Cleaning when the product is very dirty
Precautions for cleaning
Do not use the following things that can damage the surface of the product.
●
Acid cleaner, alkaline cleaner, and chlorine bleach
●
Solvents such as thinner and benzine
●
Cleaners containing rough particles such as cleanser and polishing powder
●
Nylon scrubbing brush, other brushes, etc.
Cleaning Method
Wall-mounting screw
(truss head tapping screw
φ
4 x 35)
2 pieces
Accessory parts
2
①
Mark the positions of wall-mounting screws.
②
Make prepared holes and fix the product body using 2 supplied wall-mounting screws
(truss head tapping screw
φ
4 x 35).
Product Dimensions and Accessories
<YKH20R> Single hook
<YKH21WR> Double hook
<YKH21R> Doorstop hook
Wall-mounting screw (truss head tapping screw
φ
4 x 35): 2 pieces
Reference mounting height
*Toilet booth: Finished floor s 1,600
*Ostomates’ toilet package or next to the urinal: Finished floor s 1,000
*Next to the washbasin: Finished floor s 900
Wall-mounting screw (truss head tapping screw
φ
4 x 35): 2 pieces
Reference mounting height
Finished floor s 1,700
86
37
6.5
6.5
50
50
100
100
37
6.5
6.5
50
50
Wall-mounting screw (truss head tapping screw
φ
4 x 35): 2 pieces
Reference mounting height
Finished floor s 1,700
87
6.5
6.5
100
50
Wall-mounting screw
(truss head tapping screw
φ
4 x 35): 2 pieces
Use a screwdriver with a bit
length of 100 mm or longer.
Tip
*The figure shows YKH20R.
Cleanser
Alkaline
acid
cleaner
Thinner
■
Use a plywood sheet that is 12 mm or more in thickness on the mounting surface.
Failure to do so could cause the installed product to be unstable and drop, which could result in injury.
■
When the mounting surface is a thin wall, mount a reinforcing wooden block that is 30 mm or more in
thickness before installation.
Failure to do so could cause the installed product to be unstable and drop, which could result in injury.
■
When installing the product on a partition wall, place a reinforcing wooden block of 30 mm or more in
thickness in the tapping-screw-fixing position.
Failure to do so could cause the installed product to be unstable and drop.
■
When the mounting surface is a tile or concrete wall, use a commercially available plugs for concrete, etc.
Failure to do so could cause the installed product to be unstable and drop, which could result in injury.
■
Use the supplied wall-mounting screws (truss head tapping
screw
φ
4 x 35) for installation.
Failure to do so could cause the installed product to be
unstable and drop, which could result in injury.
■
Make sure that the product has no backlash after the
installation is complete.
If the product has backlash, it could come off or the wall could
collapse, which could result in user’s fall and injury.
Finished wall surface
Finished wall surface
φ
16
φ
16
Finished wall surface
φ
16
CAUTION
CAUTION
2021.4
YP03218 T1