background image

 Thermostat Shower Mixer 

For best results, be sure to read the following installation instructions and use the product only as described in the manual. 

03C451E

2009.11

Important Safeguards 

  

(For your safety, please follow the instructions below.)        

Installation Manual 

Do not disassemble or modify the item 
in any way not described in this manual. 

 
If the system is broken, property damage, scalding and other 
injuries are likely to occur due to water leakage. 

Do not fit the pipe in opposite the intended 
temperature. 

Burns may result from confusing hot water for cold. 

Do not use hot water that is 85℃ and higher 

 
If you use hot water over 85℃, the life of the faucet will be 
reduced, if it is broken, property damage, scalding and other 
injuries are likely to occur due to water leakage.

If you want to clean the filter, shut off the stop 
valve first and do not open the cover 
abruptly. 

To use hot water as shown in the scale, you 
must adjust the temperature. 

If you do not use hot water as shown in the scale according to 
the specifications, you may be burned. 

Hot water expelled when removing the cap can burn you and 
cause injury. Use caution. 

Do NOT 

Do Not 

disassemble 

Mandatory 

Warning 

Warning 

Read the  Important Safeguards  section thoroughly before installing the product.

Warning 

Caution 

Ignoring these symbols may result in 
death or serious injury. 

Ignoring  this  symbol  may  result  in 
injury or property damage. 

 Absolutely Do NOT. 
Do not disassemble.

Mandatory! 

●The following table demonstrates 
   the use of safety symbols in this 
   manual.

Do not impact violently 

If it is broken, property damage, scalding and other injuries 
are likely to occur due to water leakage. 

Do NOT 

Caution 

The shower tower should not be used as a 
handrail or be used to hang objects. 

 

 

 
If the shower tower or the supporting wall is 
damaged, it may cause injury and leakage. 

Hot water side 

Cold water 
side 

Less than 

85℃ 

40℃ 

filter, cold side 

Filter, 
hot side 

stop valve 

shut 

Shower Tower 

Cap 

Model TMC95 V101* 

●The following symbols indicate safe and proper use 
   of the product. Failure to observe them may result in  
   injury or property damage. 
   The symbols and their meanings are as follows:

Mandatory 

reinforced 

Specifications 

Cold and hot 
water pressure 

Min.necessary 
pressure 

0.75MPa(static) 

0.15MPa(flowing pressure) 

Less than 85℃ 

Water from river or the well for drinking 

1〜40℃ 

For a general family bathroom 

Max.use temperature 

Suitable water quality 

Suitable ambient temperature 

Usage 

Sealing agent must be applied around the 
installation hole 

 

 
If sealing agent is not applied, when the wall gets wet, the 
shower tower may become detached or the wall may be damaged, 
injury may occur. 

Read the installation method of the substrate 
carefully, confirm the substrate has enough 
strength or reinforcement is installed.

 

 
Otherwise, the shower tower may become detached and the wall 
may be damaged, injury may occur. 

After installation, confirm that the shower tower 
is stable

 

 
If the shower tower is unstable, it will become detached and 
the wall will be damaged, injury may occur. 

Caution 

Must be installed on a shower wall or area 
of equal support strength. 
 

Direct installation on weak mud or plaster walls may result in 
detachment of the shower tower of damage to the wall: resulting  
in injury. 

Max. pressure 

No 

Shaking 

1/6

See next page

Reviews: