10
EN
EN
Before Installation
z
If the water supply pressure exceeds 0.75 MPa, reduce the pressure to about
0.2-0.3 MPa using a commercially available pressure reducing valve.
We recommend a water supply pressure of about 0.2-0.3 MPa for comfortable
use of the faucet.
z
In order to prevent scalding due to unsafe operation, the cold water supply
pressure must be set higher than or equal to the hot water supply pressure.
If increasing pressure on the hot water side, make sure the hot water supply
pressure side is set lower than the cold water side.
z
Set the temperature on the water heater to higher than the temperature of the
discharged water.
z
In order to prevent scalding, set the temperature of the hot water in the hot-water
supply less than 60°C.
A setting of 50°C to 60°C is recommended to ensure a comfortable discharge
temperature.
z
Connect the hot-water supply pipe at a minimum length from the water heater
in order to reduce resistance and make sure to wrap the water supply pipe with
thermal insolation.
z
Water may remain in the product from flow tests conducted before the product is
packaged, this does not indicate that something is wrong with the product.
Clean the inside of cold-/hot-water supply pipes
1
Clean the water supply and hot water supply pipes to wash off any dust or
sand from inside the pipes.
Put silicon between the water supply and hot water supply pipe and the wall.
* Dust and sand in the water supply and hot water supply pipes may clog the
filter and cause the following phenomena:
[1] A low volume of water discharge
[2] It is not possible to control the temperature
本体部の取り付け
2
Wrap sealing material around the water supply legs, attach them to the pipes
and level them.
3
Attach the "Mounting plate + functional part" to the water supply legs.
Add markings for the pilot holes for the holes (2 places) on the lower part of
the mounting plate.
4
Remove the "Mounting plate + functional part".
5
Remove the screws on the "Mounting plate + functional part" (5 places).
*The screws will be used later, so be careful not to lose them.
6
Pull the functional part out from the mounting plate.
7
Align the mounting plate to the marks marked in
3
and add markings for the
pilot holes for the holes (2 places) on the upper part of the mounting plate.
8
Open up pilot holes at the four places marked and insert concrete plugs.
9
Install the mounting plate horizontally.
10
Insert the functional part into the mounting plate and fasten it with the screws
removed in
5
.
11
Align the flanged bushing of the functional part with the flanged parts of the
water supply legs, insert the one-touch couplers and fasten them.
*If the Open/Close button and front panel are not level with each other:
[1] Pull the Open/Close button toward you and hold it in your hand.
[2] From the back, use a precision screwdriver or something with a thin tip on the
claw of the Open/Close button to remove it.
[3] Rotate the adjusting screw to adjust the front/back positioning.
[4] Align the Open/Close button with the hexagon of the adjusting screw and install
the Open/Close button.
21
Fasten the front panel to the shelf unit and the fixing frame.
22
Fasten the cover to the fixing frame.
23
Attach and fasten the cover and hanger to the fixing frame in that order.
24
Attach the temperature control handle and flow adjustment handle.
*Pay attention to the direction of the handle.
12
Rotate the one-touch couplers 90 degrees to lock the opening.
13
Insert the fixing frame into the mounting plate.
14
Use screws to fasten the fixing frame to the mounting plate.
15
Mount the shelf unit horizontally on the fixing frame and add marking for the
pilot hole at the wall fixing position.
16
Open up a pilot hole at the place marked and insert a concrete plug.
17
Fasten the fixing washer to the wall.
18
Fasten the shelf unit to the fixing washer and the fixing frame.
19
Hook the claws of the top plate to the slits of the fixing frame and attach it.
20
Attach the front panel to the main unit.