 Mount reinforcing wooden blocks that 

are 60 mm or more in thickness on the 
handrail mounting area beforehand.

 Carry out centering and then make 

prepared holes 

φ

8.5 mm for hanger 

bolts.

 

(In the case of a tile wall, make through 

holes of 

φ

11 to 13 mm only in the tile 

area.)

 Fix using the nuts (2 pieces) as a double 

nut, which come with the hanger bolts. 
(See the figure below.)

 Turn the double nuts fixed in 

 using a 

tool, and screw the hanger bolts into the 
prepared holes.

 Adjust the projecting length of the bolts 

to be between 12 and 18 mm from the 
finished wall surface.

 Remove the double nuts. 

 While carrying out centering, fix the 

mounting plate to the reinforcing 
light-gauge steel frame (t 2.3 mm or 
more) by welding.

 Screw the continuous-thread studs into 

the holes of the mounting plate, adjust 
their projecting length to be between 12 
and 18 mm from the finished wall 
surface, and tighten from the back of 
the wall with nuts.

 Finish the wall. 

7

Wooden base: Fixing with hanger bolts

Light-gauge steel base: Fixing a mounting plate by welding

12 to 18

60 or more

Reinforcing 

wooden block

Finished 

wall surface

M screw side

Note 1

Note 2

Note 3

Note 4

Screw 2 nuts and turn the nuts to the 

different directions each other to 

tighten and fix. 

Coach screw side

Prepared hole 

(

φ

8.5) for hanger 

bolt

Plywood, etc.

(Unit: mm)

Finished 

wall surface

Notes

Notes

Through hole(

φ

11)

Plywood, etc.

Continuous-

thread stud

12 to 18

Mounting plate

Nut

Welding

t 2.3 or more

Reinforcing material

(t = 2.3 or more)

Stud

Mounting plate

Note 1

Notes 2 and 3

(Unit: mm)

7

-3

. Mounting the Fixing Bracket on the Wall

Fixing bracket part number T110D25

Fixing bracket part number TT110D52

*You cannot adjust the 

mounting position of the 

handrail after finishing the wall. 

Note 1: Be sure to mount reinforcing wooden blocks that are 60 mm or more 

in thickness. 

Note 2: Use a drill that can make prepared holes of 

φ

8.5 mm in the 

reinforcing wooden blocks. If the bit size of the drill is too large or if it 
has core deviation, you may fail to fix it securely.

Note 3: Be sure to use the nuts (2 pieces) as a double nut to put the hanger 

bolt in the wall. If face nuts are used, the heads of the face nuts may 
be damaged.

Note 4: Adjust the projecting length of the hanger bolts to be between 12 and 

18 mm from the finished wall surface. 

Note 1: Use reinforcing light-gauge steel frames that are t 2.3 mm or more.
Note 2: Adjust the projecting length of the continuous-thread studs to be 

between 12 and 18 mm from the finished wall surface.

Note 3: In the case of T110D49R, be sure to install it with the indication of 

“UP” facing upward on the mounting surface. 

Summary of Contents for T112H

Page 1: ...ovable handrail to be damaged and may result in injury When the product is used in wet areas such as a restroom be sure to apply sealant around the mounting holes If sealant is not applied water may enter the back of the wall and cause the product to come off or the wall to collapse which could result in user s fall and injury Be sure to use TOTO designated fixing brackets If TOTO designated fixin...

Page 2: ...d for one handrail See Fixing Brackets Optional Parts for the required number of fixing bracket sets For fixing methods not shown in this manual contact TOTO s branch office branch shop or sales office Make sure that there is no obstacle in the handrail moving area See Completion Drawing for the moving area See the catalogue etc for the handrail installation position Check the functions of the fli...

Page 3: ...the hexagon socket head cap screws 2 pieces equally and lightly using the longer side of a hex key opposite side size 2 5 mm until the screws come in contact with the wall Change to the shorter side of the hex key and tighten the screws equally and firmly Additional tightening about 180 from the state of Hold the shorter side of the hex key Hold the longer side of the hex key to additionally tight...

Page 4: ...ndrail body Part of the shape may be different between the figure and the actual part depending on the part number Installation manual Instruction manual Handrail body T112H type Face nut M10 4 pieces Spring washer 4 pieces Use method label Paper holder unit Hexagon socket head cap screw M4 35 2 pieces 90 220 L1 150 233 173 φ34 8 8 Movable range Operation lever Building structure Fixing bracket op...

Page 5: ...en drive them in the prepared holes lightly Tighten the nuts on the anchor bolt Screw continuous thread studs into the bolt holes of the mounting plate and tighten them with nuts After finishing the wall adjust the projecting length of the continuous thread studs to be between 12 and 18 mm from the finished wall surface 12 to 18 Concrete Mortar Finished wall surface Nut Anchor bolt Prepared hole φ...

Page 6: ...lts 7 2 Mounting the Fixing Bracket on the Wall Prepared hole φ10 50 or more Anchor bolt Concrete Mortar 12 to 18 Finished wall surface 85 or more Note 1 Note 2 Note 3 Unit mm Through hole φ11 Concrete block Mounting plate Mortar Nut Washer 12 to 18 125 mm or less Continuous thread stud Nut Finished wall surface Finished wall surface 50 to 60 Reinforcing wooden block Washer Through hole φ11 Nut Mo...

Page 7: ...ns each other to tighten and fix Coach screw side Prepared hole φ8 5 for hanger bolt Plywood etc Unit mm Finished wall surface Notes Notes Through hole φ11 Plywood etc Continuous thread stud 12 to 18 Mounting plate Nut Welding t 2 3 or more Reinforcing material t 2 3 or more Stud Mounting plate Note 1 Notes 2 and 3 Unit mm 7 3 Mounting the Fixing Bracket on the Wall Fixing bracket part number T110...

Page 8: ...e 1 Note 1 Note 2 Note 2 Through hole φ16 Continuous thread stud 12 to 18 Mounting bracket Mechanical nut Through hole φ11 Plywood etc Plywood etc Prepared hole φ8 5 for M10 tapping Continuous thread stud Finished wall surface Finished wall surface 12 to 18 Mounting bracket Stud Mounting bracket Reinforcing material t 2 3 or more Unit mm Make sure that the handrail has no backlash Checking for bac...

Page 9: ...Center position of the upper bar T112H Type T113H Type T114H Type The marks indicate the positions of prepared holes 90 220 ...

Reviews: