Installation Procedure

ENGLISH

4

Information below should be observed in order to properly install the shower.

   7-7/8”

(200 mm)

   15-3/4” (410 mm)

       39”  (1000 mm)   from the floor

      44”  (1100 mm)

Location of 

Showerhead

Location of 

wall spout

Location of 

Thermostatic

Mixing valve

Location of 

Dual Volume 

Control Valve

Location of 

Single Volume 

Control Valve

Location of 

HandShower

Adapter

FLOOR

   7-7/8”

(200 mm)

Showerhead

Wall Spout

1/2” pipe

Single Vol 

Control 

Valve

Dual Vol 

Control 

Valve

          Hand Shower

              Adapter

(TRIM is to be installed here.)

Thermostatic 

Mixing Valve

Preparation

Plumbing Setup

HOT

COLD

Hand Shower Trim does not have direct water connections or volume control; 

those items need to be purchased separately (See the Shower Setup Options) 

Each item is 

sold separately.

Refer to Handshower Adapter Installation manual 

for detailed installtion procedure of the adapter.

Caution

MIN

Guard 

cover

MAX

FINISHED

WALL

2-15/16” (75mm) MIN

3-9/16” (90mm) MAX

① 

After confirming the rough-in of the adapter provided,

     connect the adapter with the Single Volume Control

     Valve (SOLD SEPARATELY).

Leave the guard covers on the valves 

till the tile work  is completed.

② 

Make sure with the guard cover provided

that distance between Finished Wall surface and 

valve falls between MIN and MAX. 

Caution

From Thermostatic 

Mixing Valve

           Hand Shower

              Adapter

1/2” pipe

Guard cover

Single Vol 

Control 

Valve

TOTO mark on top  

Summary of Contents for RENESSE TS170F

Page 1: ...sure the safe use of your product Installation and Owner s Manual 2007 5 0GU3031 TS170F Important Safeguards 1 Specifications 2 Before Installation 2 Set up Drawing 3 Components 3 Installation Procedu...

Page 2: ...erious injury Failure to observe this symbol may result in injury or property damage Absolutely Do NOT Do not disassemble Mandatory O ring Freezing Do Not Caution If the system is broken property dama...

Page 3: ...to reduce the pressure to the range of 0 2 0 3MPa To use the faucet comfortably the recommended pressure is about 30 45 psi 0 2 0 3MPa To prevent being scalded due to malfunction the cold water suppl...

Page 4: ...lation manual Shower joint Hand shower Shower hanger hanger Screws 2 pieces Mounting beads 2 pieces Mounting plate gasket screws 2 pieces Hand shower coverplate set Shower set Tools you will need 1pie...

Page 5: ...Shower Trim does not have direct water connections or volume control those items need to be purchased separately See the Shower Setup Options Each item is sold separately Refer to Handshower Adapter I...

Page 6: ...and fasten the face plate nut Position the notch below and press the escutcheon into the face plate If the escutcheon is difficult to attach apply weak soapy water to the O ring Then tighten the Hand...

Page 7: ...Bath Spout TS170E CP Hand Shower Trim TS170F CP Single Volume Control Trim for Hand Shower TS170C1 CP Hand Shower Adapter TSKH Thermostatic Mixing Valve Trim TS170T CP Mixing Valve SMA Thermostatic T...

Page 8: ...ct to be free from defects in materials and workmanship for one 1 year from the date the Product is installed with all other terms of this warranty applicable except the duration of the warranty 5 THI...

Reviews: