INSTALLATION PROCEDURE

9. Insert the drain lift rod through 
the opening in the spout.

Drain Lift 
Rod

Insert the drain body up through 
the drain hole from below the 
lavatory. If necessary, turn the 
nut and push the washer and 
gasket (thick) down to allow for 
clearance.
While holding the drain body in 
place, fasten the flange to the 
drain body from the top. Ensure 
that the gasket (flat) is between 
the flange and the lavatory as 
shown. Once the flange is fully 
seated, turn the nut below the 
lavatory up until a good seal is 
formed. Do not overtighten!

Reinsert the plunger if needed.

Drain

10. Remove the plunger, flange and gasket 
from the drain assembly by unfastening 
the flange and pulling these parts from the 
drain.

Plunger

Flange

Gasket

Gasket (thick) 

Washer

Nut

Body

Tailpiece

Lever Hole

Plunger Hole

Lever Hole

Bushings

Pivot Ball Nut

Pivot Arm

Short End

Long End

Summary of Contents for GO TLG01201U

Page 1: ...E SOLE PROPERTY OF TOTO USA INC ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF TOTO USA INC IS PROHIBITED THIS DRAWING IS CONTROLLED BY TOTO USA INC MORROW ANY CHANGES TO THI...

Page 2: ...static Do not use the product at an ambient temperature below 32 F 0 C Observe all local plumbing codes Before installing the faucet be sure to thoroughly flush the supply pipes of dirt and debris Ma...

Page 3: ...551 kPa Water Supply Connection NPSM 1 2 Ambient Temperature 32 104 F 0 40 C Humidity Max 90 RH Flow Rate Maximum 1 2 gallon min 4 5 L min Aerator Key Drain Lift Rod Spout Assembly Handle Assembly 2x...

Page 4: ...Fixate the valve by threading the mounting nut up the valve until hand tight Tighten the retaining screws equally to secure Do not overtighten 4 Repeat steps 1 3 for remaining valve NOTE Hoses to con...

Page 5: ...eeded be careful not to crimp the hose at any point at this could restrict the water flow Handles 8 Orient handle assembly and lower onto the exposed portion of valve until engaged Fasten handle escut...

Page 6: ...he drain body from the top Ensure that the gasket flat is between the flange and the lavatory as shown Once the flange is fully seated turn the nut below the lavatory up until a good seal is formed Do...

Page 7: ...t arm by placing one bushing on each side of the pivot ball as shown Insert the short end of the rod into the drain body and through the eyelet hole in the plunger Fasten the pivot ball nut to secure...

Page 8: ...roduct at the purchaser s location or pay to transport the Product to a service facility THIS WRITTEN WARRANTY IS THE ONLY WARRANTY MADE BY TOTO REPAIR REPLACEMENT OR OTHER APPROPRIATE ADJUSTMENT AS P...

Page 9: ...i 551 kPa est tico No use el producto a una temperatura ambiente inferior a 32 F 0 C Observe todos los c digos de plomer a locales Antes de instalar el grifo aseg rese de enjuagar a fondo los tubos de...

Page 10: ...e suministro de agua NPSM 1 2 Temperatura ambiente 32 104 F 0 40 C Humedad Max 90 RH Flujo Maximo 1 2 gallon min 4 5 L min Llave del Aireador Vara de Desag e Ensamblaje de salida para tina Ensamblaje...

Page 11: ...montaje hasta que est ajustada De igual manera ajuste los tornillos de retenci n para asegurarlos No ajuste dem s 4 Repita los pasos de 1 a 3 para la otra v lvula NOTA Las mangueras para conectar las...

Page 12: ...zar la manguera en ning n punto ya que esto podr a restringir el flujo de agua Manijas 8 Oriente el ensamblaje de la manija y b jelo hacia la parte expuesta de la v lvula hasta que encastre Sujete el...

Page 13: ...desag e desde la parte superior Aseg rese de que el perno chato est entre el reborde y el lavabo como se muestra Una vez que el reborde est completamente asentado gire la tuerca de abajo del lavabo ha...

Page 14: ...cada lado de la bola de pivote como se muestra Inserte el extremo corto de la vara en el cuerpo del desag e y a trav s del orificio del ojal en el mbolo Ajuste la tuerca de la bola de pivote para ase...

Page 15: ...o a un servicio t cnico ESTA GARANT A POR ESCRITO ES LA NICA GARANT A REALIZADA POR TOTO LA REPARACI N REEMPLAZO U OTRO AJUSTE ADECUADO TAL COMO APARECE EN ESTA GARANT A SER EL NICO RECURSO DISPONIBLE...

Page 16: ...i 551 kPa statique Ne pas utiliser le produit une temp rature ambiante inf rieure 32 F 0 C Respectez tous les codes de plomberie locaux Avant d installer le robinet assurez vous de bien rincer les tuy...

Page 17: ...Raccordement d alimentation en eau NPSM 1 2 Temp rature ambiante 32 104 F 0 40 C Humidit Max 90 RH D bit Maximum 1 2 gallon min 4 5 L min Cl de l a rateur Tige de Levage du Drain Assemblage du Robinet...

Page 18: ...vanne en vissant l crou de montage sur la vanne jusqu ce qu il soit serr la main Serrez galement les vis de retenue pour la fixer Ne serrez pas excessivement restante les admissions de vanne aux cond...

Page 19: ...pincer le tuyau sur aucun point car cela pourrait limiter le d bit Poign es 8 Orientez l assemblage de la poign e et abaissez le sur la partie expos e de la vanne jusqu ce qu elle soit engag e Fixer...

Page 20: ...ir du haut Assurez vous que le joint d tanch it plat est entre la bride et le lavabo comme illustr Drain 10 D posez la ventouse la bride et le joint d tanch it de l assemblage du drain en desserrant l...

Page 21: ...a ant une bague sur chaque c t de l crou rotule comme illustr Ins rez l extr mit courte de la tige dans le corps du drain et travers l illet situ sur la ventouse Serrez l crou rotule pour le fixer Ins...

Page 22: ...FFERTE PAR TOTO TOUTE R PARATION TOUT REMPLACEMENT OU TOUT AUTRE AJUSTEMENT N CESSAIRE COUVERT PAR CETTE GARANTIE SERA LA SOLUTION EXCLUSIVE LA DISPOSITION DE L ACHETEUR ORIGINAL TOTO N EST PAS RESPON...

Page 23: ...a 80 psi 551 kPa est tico N o use o produto a uma temperatura ambiente abaixo de 32 F 0 C Observe todos os c digos locais de encanamento Antes de instalar a torneira certifique se de esvaziar completa...

Page 24: ...51 kPa Conex o de fornecimento de gua NPSM 1 2 Temperatura ambiente 32 104 F 0 40 C Umidade Max 90 RH Vaz o Max 1 2 gallon min 4 5 L min Chave do Aerador Haste de Eleva o de Dreno Conjunto do Bico Con...

Page 25: ...rca de montagem para cima at a v lvula at ficar apertada Aperte os parafusos de reten o por igual para garantir N o aperte demais 4 Repita as etapas 1 3 para o restante na v lvula OBSERVA O Mangueiras...

Page 26: ...la o tenha cuidado para n o engolir a mangueira em qualquer ponto isto pode restringir o fluxo de gua Al as 8 Direcione o conjunto da al a e abaixe na parte exposta da v lvula at ficar engatada Aperte...

Page 27: ...corpo do dreno da parte superior Verifique se a gaxeta plana est entre a flange e o lavat rio conforme mostrado Ap s o flange ficar totalmente encaixado gire a porca abaixo do lavat rio at fazer uma b...

Page 28: ...ado colocando uma bucha em cada lado da esfera do piv como mostrado Insira a extremidade curta da haste no corpo do dreno e atrav s do orif cio do olhal do mbolo Aperte a porca da esfera do piv para f...

Page 29: ...e servi os de produtos da TOTO ou 3 se devido ao tamanho do Produto ou natureza do defeito o Produto n o puder ser devolvido a um centro de assist ncia autorizado da TOTO a TOTO pode optar por reparar...

Page 30: ...30 88mm 88mm 64mm 2 3 8 2 3 16 5 127mm 6 152mm 4 1 8 105mm 4 3 16 107mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm Red Blue 55mm Mounting Hole 1 5 16 1 7 16 33mm 37mm...

Page 31: ...Faucet Red 6 5 8 169mm 4 5 8 118mm 2 3 8 60mm Max 11 1 4 285mm 1 1 4 31 75mm 15 3 3 4 96mm 7 15 16 202mm 3 76mm L 15 3 4 400mm NPSM 1 2 2 3 16 55mm 1 7 8 47mm 1 7 8 48mm 5 16 8mm Max 1 3 4 45mm 4 1 16...

Page 32: ...t water 3 15 16 100mm 3 15 16 100mm 3 3 8 86mm 3 3 8 86mm 9 0 9 0 Cold water Open Open Close Close Red Blue 6 152mm 3 15 16 112mm 2 3 8 60mm Max 11 1 4 285mm 1 1 4 31 75mm 15 4 13 16 122mm 7 15 16 202...

Page 33: ...33 NOTES...

Page 34: ...34 NOTES...

Page 35: ...35 NOTES...

Page 36: ...For product warranty registration TOTO U S A Inc recommends online warranty registration Please visit our web site http www totousa com If you have questions regarding warranty policy or coverage plea...

Reviews: