Installation Procedure

Test Run

Note to the installer

7

6

Adjustment

Step 1  (For New Installation)

Escutcheon

White

White(Toilet type)

Yellow(Urinal type)

Yellow

Battery

Covering tube

Control Stop

Adapter

Min.4-1/4"(107mm)

Max.5-1/4"(133mm)

Install the control stop using a proper size escutcheon and

1. For left water supply, attach the sensor top cover in the 

opposite direction so that the sensor will be at the front.

2. For retrofit installation, remove the old flush valve after 

shutting off the control stop.

sweat solder adapter kit if applicable. Thread sealing

compounds should be used on male NPT threads only. The

distance from center of the control stop to center of the flush

valve should fall within 4-1/4" to 5-1/4"(107mm to 133mm).

Step 2

Determine  the  length  of  vacuum  breaker  tube  to  join  the

flush valve and fixture spud. Cut the vacuum breaker tube,

if  required,  to  the  proper  length.  Assemble  the  spud  nut

assembly  to  the  fixture  spud.  Hand   tighten  spud  nut  to

fixture.

For sweat solder

Right Water Supply

Left Water Supply

Step 5

Connect the connectors of solenoid valve

and generator with those of controller.

Step 3

Prior to inserting the flush valve tailpiece into the control stop, 

be certain that the O-ring is in the groove at the end of the 

tailpiece, the locking nut and the snap ring are located as 

shown. Connect the flush valve with the control stop and the 

vacuum breaker tube. Care should be taken not to damage the 

O-ring when inserting the tailpiece into the control stop. 

If lubrication is needed, wetting the O-ring with water will be 

sufficient. Align the flush valve and securely tighten fixture spud 

nut, vacuum breaker tube nut and locking nut with a wrench.

Step 4

Connect the connector of the battery with that of the controller 

and set it at the proper position as shown below.

Step 6

Fasten  the  sensor  top  cover  on  body  cover  with  the

supplied screws (use supplied allen wrench).

Step 7

Before  the  supply  water  is  turned  on,  be  sure  all  water

leaks are eliminated by tightening all the pipe connections.

If  for  any  reason  it  becomes  necessary  to  remove  the

control stop , be certain the water is shut off at the main

supply valve. 

Pipe connection

Pipe connection

Pipe connection

Escutcheon

Joint tube

Cap

Step 8

The flush valves are preset for fixture volume as marked

on the valve carton. The valve does not require adjustment

for  variation  in  water  pressure  within  its  operating  range.

To  set  the  flush  valve  for  proper  operation,  open  the

control stop completely by using the adjusting screw and

flush  the  flush  valve  several  times.  Gradually  adjust  the

control stop closed, using the adjusting screw, so that the

rate  of  water  flow  into  the  fixture  is  not  excessive,  yet  is

sufficient  to  adequately  evacuate  the  waste.  The  cap  for

the  control  stop  should  be  placed  after  final  adjustments

have been made. Tighten the cap firmly with a wrench.

1. Make sure the control stop is open.
2. Sit on the toilet seat. (for Toilet flush valve)

Stand  within  two  feet  from  the  front  of  the  flush  valve.

(for Urinal flush valve)

3. Stay there for 6 seconds or more and then leave the

toilet seat or the urinal. The valve will automatically flush.

4.  Press  the  manual  flushing  button  and  make  sure  the

valve flushes properly and the sensor red light is on for 

2 seconds.

5. Recheck all the pipe connections for water leaks.  If the

flush  valve  is  not  operating  properly  following  the  test

run consult the Troubleshooting section of the Owner's

Manual. 

After  the  flush  valve  unit  has  been  installed  correctly,

please explain to your customer how to use it and tell them 

to observe the following instructions.
1.  Do  not  put  any  object  in  front  of  the  sensor  window

which  could  obstruct  the  sensor,  causing  it  to

malfunction.

2. For troubleshooting, consult the Owner's Manual.

If  you  lack  the  necessary  skills  required  or  have

difficulty  following  the  directions  for  installation,

maintenance,  repairs,  troubleshooting  or

adjustments, of the product, do not proceed without

help  from  a  qualified  person  to  assist  you  in

performing any of these functions.

1.  Adjustment of the discharge quantity

(1) Remove the sensor top cover.

(2) Adjust the discharge quantity by rotating the screw

on the piston valve.

2. Adjustment of the flow rate

Adjust the flow rate by turning the screw of the control

stop.

Turn the screw to the right to decrease the flow rate and 

turn it to the left to increase.

3. Adjustment of the detection range

The  detection  range  of  the  infrared  sensor  does  not

need to be adjusted because it has been factory-preset.

Printed in September, 2007

8

Friction Washer

Vacuum Breaker

Tube Nut

Spud Nut

Slip Gasket
Rubber Gasket
Escutcheon

To increase

To decrease

Control stop

Note

Control stop

Snap ring

O-ring

Supplied

Allen wrench