Installation 
Template

详细尺寸可在第19页确认。

Refer to 19 page for more 
detail dimensions.

请前往第16页。

Proceed to page 16.

装修墙厚度范围20~60mm 
(从固定支架外面算起,到贴砖后完成面)

The thickness of fixed wall is 20~60mm 
(measured from the front of frame to the finished tile surface)

ሆƥ
ሔྰు࿿࣓ൗႯ౥ᇐç
ၥєྠç҉ӼᇞҒਟƗ
೉ƥ஥ଗç്ְۢ

It is forbidden to use 
unsustainable, ductile or 
light-weight material to fix the 
covering. Such as foam board 
etc.

20-60mm

最大3mm

max.3mm

最大3mm

max.3mm

610m

m

320m

m

0

FFL

180mm

推板 226mm

Push Plate 226m

m

140m

m

排水管孔

Outlet

 Drain Hole

电源孔

Power Supply 
Hole

卫洗丽用进水管孔

WASHLET Water Supply Hole

进水管孔

Inlet Drain Hole

马桶安装孔

Toilet

 Mounting

Hole

s

进水管挡
泥堵头

Inlet Drain
mud guard

排水管挡泥堵头

Outlet Drain
Mud Guard

预留推板

Push Plate
Rough-In

螺纹安装柱

Threaded 
Mounting 
Stud

20~60mm

10mm

接线盒孔

Elec

trical Box Hole

15

!

!

׮໑௒

Installation 
Template

详细尺寸可在第19页确认。

Refer to 19 page for more 
detail dimensions.

装修墙厚度范围20~60mm 
(从固定支架外面算起,到贴砖后完成面)

The thickness of fixed wall is 20~60mm 
(measured from the front of frame to the finished tile surface)

ሆƥ
ሔྰు࿿࣓ൗႯ౥ᇐç
ၥєྠç҉ӼᇞҒਟƗ
೉ƥ஥ଗç്ְۢ

It is forbidden to use 
unsustainable, ductile or 
light-weight material to fix the 
covering. Such as foam board 
etc.

20-60mm

610m

m

320m

m

0

FFL

180mm

推板 226mm

Push Plate 226m

m

140m

m

排水管孔

Outlet

 Drain Hole

卫洗丽用电源孔

WASHLET Power Su

pply Hole

进水管孔

Inlet Drain Hole

马桶安装孔

Toilet

 Mounting

Hole

s

进水管挡
泥堵头

Inlet Drain
mud guard

排水管挡泥堵头

Outlet Drain
Mud Guard

预留推板

Push Plate
Rough-In

螺纹安装柱

Threaded 
Mounting 
Stud

20~60mm

10mm

电源孔

Power Supply 
Hole

卫洗丽用进水管孔

WASHLET Water Supply

 

Hole

在墙壁上涂覆砂浆或类似材料时,请务必覆盖
电缆以避免将其固定。

When working on the wall using mortar or the like, be sure 
to cover the cable so that it is not fixed in place.

最大3mm

max.3mm

最大3mm

max.3mm

Summary of Contents for CW812REA

Page 1: ...WH173BAT WH172AAT WH173BAT WH172AAT WH173SGAT 563414 1...

Page 2: ...actuator panel instructions 2 This instruction manual only supports the installation of the concealed cistern 3 For Australia the installation has to be in accordance with AS NZS 3500 series of Standa...

Page 3: ...erwise burn or trouble with equipment may be caused CAUTION WARNING Install a ground fault interrupter or insulation transformer Morethan0 6m Power plug Do not give direct impact to the product Otherw...

Page 4: ...of the cistern and flush valve sand or debris lodged in during installation 2 The exposed part of the panel s adjust screw is too long which resulting the rubber of flush valve can not fixed in a cert...

Page 5: ...the wall is the main wall the thickness exceed 80mm and it can bear more than 300kgf strength when the strength act on the front of toilet bowl 1 Please install the frame before paving the tiles The...

Page 6: ...2 Lower Bracket Anchor 6 Cable Tie Lag Screw 6 Bolt 4 Angle Fixture Angle Valve Bolt 4 Nut 4 Nut 2 Cap 2 Washer 2 Stud Bolt Flange 2 Flange Pipe Inlet Pipe Lubricated Sponge Push Plate Rough In Push...

Page 7: ...heir meanings 580 40 R1 2 Mark the location Mark Before Installation Installation procedure 1180 180 230 320 1000 650 1165 100 220 35 FFL 0 35 15 135 152 134 0110 Main wall 135 220 20 60 70 130 200 22...

Page 8: ...D C A B B A A FFL 0 220 Install the discharge pipe Install Angle Fixture and adjust floor fixing bracket UU 170 Bolt length of 75 mm UU 170 Bolt length of 120 mm Install the branch pipe Adjust floor f...

Page 9: ...inage pipe exceed 45 Pull the power supply cable from the corrugated pipe as shown in the figure below 10mm Use provided cable tie to secure the power supply cable in place with an additional 10mm ext...

Page 10: ...L 490 152134 650 Horizontal Vertical 60mm Depth 60 mm B C B A A C As shown on picture 1 Drill 10 60 2 Insert anchor 10X 60 Draw on the main wall and floor Install Anchors 0 0 0 Adjust horizontally and...

Page 11: ...11 1 19 2 3 1 1 2 1 2 3 Sealing Tape Sealing Tape Click Click Install the Angle valve B C D E A Install the water supply pipe Click Click Click Click...

Page 12: ...on the bracket which are of different distance Please choose the right position according to the size of the toilet bowl Important remind When the concealed tank fixed completely it is important to te...

Page 13: ...g on WASHLET being installed 14 For WASHLET with an attached outlet plug proceed to page 14 15 For WASHLET with the above plug attached proceed to page 15 Power plug shape may vary by country Please c...

Page 14: ...rbidden to use unsustainable ductile or light weight material to fix the covering Such as foam board etc 20 60mm 3mm max 3mm 3mm max 3mm 610mm 320mm 0 FFL 180mm 226mm Push Plate 226mm 140mm Outlet Dra...

Page 15: ...the covering Such as foam board etc 20 60mm 610mm 320mm 0 FFL 180mm 226mm Push Plate 226mm 140mm Outlet Drain Hole WASHLET Power Supply Hole Inlet Drain Hole Toilet Mounting Holes Inlet Drain mud guar...

Page 16: ...aight Pipe just as shows Mark lines as shows Add lubricant onto the Rubber Gaskets of two Straight Pipes and set them into Bowl 7 Take out the sponge with silicon oil and smear it on connecting edges...

Page 17: ...n bracket Tilt the two pull up rods of the flush valve to the right Remove the relay harness from the auto flush unit Make sure that the cord does not get wet after removing it Remove the hold down br...

Page 18: ...then remove the fill valve as described above 2 As shown in the figure disassemble the fill valve and then either clean the filter with water or use a brush to clean any dirt from it 3 To install foll...

Page 19: ...mm 19mm 64mm 78mm 340mm 460mm min 340mm max 460mm 35mm 100mm 260mm 320mm 305mm Electrical Box Hole 40mm 24mm FFL 180mm 19mm 24mm 24mm 40mm 114mm 19mm 64mm 78mm 35mm 40mm 90mm 100mm 260mm 320mm Detail...

Page 20: ...siness Centre 360 Kim Ma St Ba D nh Dist Ha Noi City Phone 84 4 37714354 Fax 84 4 37714355 http toto com vn Manila Representative Office Unit 1010 10th Floor Rufino Building Ayala Avenue cor V A Rufin...

Reviews: