TotalPond UVC9 Manual Download Page 2

PREPARATION 

Before beginning assembly of product, make sure all parts are present. Compare parts with package 
contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or 
operate the product. Contact customer service for replacement parts. 
 

 

Estimated Assembly Time: 30 minutes  

 

No Tools Required for Assembly 
 

IMPORTANT NOTES 

 

This product will not operate unless it is fully assembled with the lamp base screwed completely into 
the housing.   

 

UV rays are harmful to your eyes and skin.  The indicator portal will remove the harmful effects of the 
UV light but still allow you to see the bulb operating. 

 

Do not attempt to operate this product unless the lamp is completely assembled within the light 
housing. 

 

This product conforms to the Code of Federal Regulations (CFR) requirements including, Title 21, 
Chapter 1, Subchapter J, Radiological Health. 

 

 

 

 
 

 

 
 
 
 

ASSEMBLY INSTRUCTIONS 

 

1.  The adapters included can connect to 1/2-in., 3/4-in. or 1-in. 

tubing.  Note that 3/4-in. tubing is recommended for optimum 
performance.  If using 1/2 in. ID tubing, proceed to step 2.  If 
using 3/4 in. ID tubing, cut the adapter as shown using a 
hacksaw.  Fig. 1 

  
 
                  
 
                                                                                                   
 

 

                                                                                                                    

Fig. 1 

 

2.  Install the adapter gasket, adapter, and adapter locking nut  

onto the inlet and outlet of the lamp housing.  Fig.2 

 

 

  NOTE: For a proper seal, the parts must be installed in this 
              specific order. 

 
 
 
 
 
 
                                                                                                                                            

Fig. 2 

Specifications 

Lamp Voltage 

60V 

Lamp Current 

0.2A 

Lamp Power 

9 W 

Rated Frequency 

60 Hz 

UV Irradiance 

35 µW/cm

2

 

Bulb Life 

8000 hours 

Bulb Model Number 

UVRB 

UV Wave Length 

UV(C) · 254 nm 

 

 

Gasket 

Adapter 

Locking nut 

 

Cut ring 

 

Summary of Contents for UVC9

Page 1: ...ll reduce the risk of electric shock by providing a path of least resistance for electric current This appliance is equipped with a cord having an appliance grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances CAUTION UV light may cause irritation to the skin and or eyes Avoid e...

Page 2: ...he lamp is completely assembled within the light housing This product conforms to the Code of Federal Regulations CFR requirements including Title 21 Chapter 1 Subchapter J Radiological Health ASSEMBLY INSTRUCTIONS 1 The adapters included can connect to 1 2 in 3 4 in or 1 in tubing Note that 3 4 in tubing is recommended for optimum performance If using 1 2 in ID tubing proceed to step 2 If using 3...

Page 3: ...n the lamp housing Fig 4 5 Plug the PCUV9 into a properly grounded electrical outlet Fig 5 Fig 5 6 Wait several seconds for the light to turn on then check the indicator light to verify if the light is functioning correctly Fig 6 NOTE This clarifier has a safety feature that only allows the UV light to turn on if the lamp holder is fully seated into the lamp housing Fig 6 Pump not included Tubing ...

Page 4: ...der Fig 8 Fig 8 3 Carefully remove the old bulb by firmly pulling on the base Carefully install the new bulb Fig 9 Fig 9 4 Reinstall the lamp holder and locking ring Fig 10 NOTE This clarifier has a safety feature that only allows the UV light to turn on if the lamp holder is fully seated into the lamp housing Fig 10 Locking Ring Old bulb New bulb Locking Ring Lamp holder Lamp holder Lamp holder L...

Page 5: ...nect the UV light from the outlet Be sure to allow sufficient time for the light to cool before disassembling the light 2 Unscrew the locking ring and pull out the light unit 3 Carefully pull out the glass tube holder by twisting and then pull out 4 Use warm soapy water to clean the glass tube Be sure to use biodegrable soap 5 Reassemble the UVC9 and be sure that all gaskets and o rings are seated...

Page 6: ...ter D Adapter nut E Lamp holder F Lamp holder gasket G Bulb holder H Glass tube holder I O ring 1 J Glass tube gasket K Glass tube L Glass tube locking nut M O ring 2 N Lamp housing TotalPond replacement UV bulbs can be purchased at Home Depot Item UVRB F E J H M K G B N C D L I 6 ...

Page 7: ...products or parts subject to this warranty For products damaged in transit a claim should be filed with the carrier Disclaimer Any oral statements made about the product by the seller the manufacturer the representatives or any other parties do not constitute warranties should not be relied upon by the user and are not part of the contract for sale The seller s and manufacturer s only obligation a...