background image

1 GENERAL POINTS

Read this documentation carefully before installation.

Installation and functioning must comply with local and national safety regulations in force in

the country where the product is to be installed.

The entire operation must be carried out in a workmanlike manner.

Failure to comply with the safety regulations not only causes risk to personal safety and

damage to the equipment, but also invalidates any right to warranty assistance.

Keep this manual in a safe place for further consultation even after the first installation.

2 APPLICATIONS

These electro

 

pumps find use systems for lifting water from wells, first collection tanks or cisterns,

streams, to basement

 

pump out (cellar, garages), to swimming pools pump out and small

agricultural installations, sprinkling systems for gardens and allotments. When installed in wells or

tanks, the pump, which is particularly silent running, avoids all problems related to suction and loss

of priming.

The pump may be supplied with a float switch cutting out operation automatically in the event of an

insufficient water level

.

These pumps cannot be used in swimming pools, ponds or tanks in which people are

present, or for pumping hydrocarbons (petrol, diesel fuel, fuel oils, solvents, etc.) in

accordance with the accident-prevention regulations in force.

N.B.

: The liquid employed in the pump for lubricating the sealing device is not toxic, but it could

alter the water properties (in the case of pure water) if there were any leaks in the seal.

3 PUMPED FLUIDS

The machine has been designed and built for pumping water, free from explosive substances,

and solid particles or fibres, with a density of 1 Kg/dm³ and a kinematic viscosity of 1mm²/s,

and chemically non-aggressive liquids.

4 TECHNICAL DATA AND USE LIMITATIONS

-

Supply voltage

:

see electric data plate

-

Absorbed power:

see electric data plate

-

Maximum working pressure:

1 Bar

-

Degree of motor protection:

IP 68

-

Thermal class:

F

-

Liquid temperature range:

from 0°C to +50°C

-

Maximum immersion

:

5 metres

-

Storage temperature

:

from -10°C to +40°C

2

Summary of Contents for TWP7110016

Page 1: ...SUBMERSIBLE PUMP SCAN FOR VIDEO SCAN FOR VIDEO TWP775016 TWP7110016 TWP775016 5 TWP7150026 UTWP7150026 TWP7150026 5 TOTAL TOOLS WORLD...

Page 2: ...related to suction and loss of priming The pump may be supplied with a float switch cutting out operation automatically in the event of an insufficient water level These pumps cannot be used in swimmi...

Page 3: ...le to which a rope or cable may be connected to lower the machine into working position The pumps must never be carried lifted or operated hanging from their power cables Qualified personnel must be e...

Page 4: ...y kind of choking of the output pipe It is advisable to use pipes with an internal diameter at least equal to that of the delivery pipe so as to avoid a fall in the performance of the pump and the pos...

Page 5: ...tream from the pump fit a suitably sensitive magnetothermal differential switch Switch off the power upstream from the system before making the electrical connection Single phase motors are provided w...

Page 6: ...s 1 Start the pump and observe the water flow rate 2 Stop the pump switch off the power and invert two phases on the supply line 3 Restart the pump and check the water flow rate again 4 Stop the pump...

Page 7: ...oes not require any type of maintenance thanks to the oil bath lubricated seal and to the greased for life bearings The electro pump can only be dismantled by skilled and qualified personnel in posses...

Page 8: ...top A The float does not interrupt the operating of the pump A Make sure float moves freely and check its efficient 4 The flow rate is insufficient A Ensure that the suction filter is not partly block...

Page 9: ...in matter 14 TECHNICAL DATA Model No Voltage V Frequency Hz Phase Rated output kW HP No load speed min Max head m Max flow m3 H Inlet Outlet inch Cable length m 220 240 50 Single 0 75 1 0 2850 13 21 2...

Page 10: ...10 TWP775016 TWP7110016 TWP775016 5 Exploded view...

Page 11: ...1 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 Stator Undulated washer Bearing Rotor Bearing Screw Washer Connection part Mechanical seal O ring Oil chamber cover Screw Washer O ring Screw Oil seal Im...

Page 12: ...TWP7150026 UTWP7150026 TWP7150026 5 Exploded view 12...

Page 13: ...cover Bearing Rotor Bearing Stator No Part Description Qty 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 Casing O ring Screw Washer Oil chamber Mechanical seal O ring Oil chamber cover...

Page 14: ...SUBMERSIBLE PUMP MADE IN CHINA T0821 V05 www totalbusiness com TOTAL TOOLS CO PTE LTD No 45 Songbei Road Suzhou Industrial Park China AFTER SALES QR CODE...