SAFETY INSTRUCTIONS

Please  note:  Before  assembling  and  putting  the  pump  into  operation,  in  all  cases  read 

through the operating manual. For safety reasons, those persons who have not read through 

the operating manual may not use the pump. The pump is intended for use ONLY by adults 

who have fully read and understand these instructions. Whenever  Water and Electric are in 

the same place there are risks of electrocution and serious injury or death. The pump is ONLY 

intended for use with water or water based (aqueous solutions) which have a content of at  

least 90% water. DO NOT use this pump for flammable,toxic, corrosive or irritant fluids.

a)  The user is responsible towards third parties with regard to the use of the pump

     (water installations, etc.)

b)  Before putting into operation, a qualified electrician must check that the required electrical

     safety measures are place.

c)  The electrical connection is to be made via an electrical socket.

d)  Check the voltage.The specified technical information on the label must correspond to the

     voltage of the electrical equipment.

e)  During the operation of the pump, persons may not remain in the pumped   medium.

f )  The temperature of the fluid to be pumped may not exceed 35°C. In the event that

     extension cables are used, they must be exclusively made out of rubber, type H07 RN-F,

     and in compliance with norm DIN 57282 or DIN 57245. Never handle, lift or carry the pump

     connected to electrical power by the cord. Make sure that the  connection power outlet is

     kept away from water and moisture and that the  power plug is protected from moisture.

g)  Before putting the pump into operation,check that the electrical cord and electrical residual

     current circuit breaker are not damaged.

h)  In the event that the pump is to be installed in a storm drain, one must subsequently close

     the storm drain with a cover in order to safeguard the safety of pedestrians.

i )  Reinforce the mounting of the discharge pipe with the use of a pipe clip.The user of the

     pump has the duty to take precautionary measures (installation of an  alarm device,

     back-up pump, etc.) for the avoidance and prevention of potential damages (such as

     flooded rooms, etc.) due to faulty pump operation (because of  breakdowns or defects).

     On sandy or silty ground it is necessary to let the pump run hanging by a rope or chain or

     to situate the pump on a suitable base in order to prevent the sinking of the intake section.

j )  In the event that the pump is damaged, the repair should only be made by an authorised

     service agent. Only original replacement parts must be used.

k)  The failure to correctly use, clean and maintain the pump or to modify the pump or its

     accessories in any way other than that described in these instructions will prevent use for

     accepting any responsiblity for damages,loss or injury.The following illustrate some of the

     cases where claims be refused :

     ● Inappropriate repairs not made by an authorised agents

     ● Use of other than original replacement parts.

i )  The connecting cable of this device may not be replaced. In the event of damage to the

     cable,the device should be scrapped.

m) Note this product has internal lubricant which may escape contaminating the water,

     consequently the pump is not suitable for ponds with fish or other aquatic organisms.In

     addition the pump can only be used to with water that is NOT for drinking at a later date.
The same rules apply for the accessories.

2

Summary of Contents for TWP311001

Page 1: ...TWP37501 TWP311001 TWP315001 UTWP37501 UTWP311001 UTWP315001 TWP47501 TWP411001 TWP415001 UTWP47501 UTWP411001 UTWP415001 SELF PRIMING JET PUMP One Stop Tools Station...

Page 2: ...he pump into operation check that the electrical cord and electrical residual current circuit breaker are not damaged h In the event that the pump is to be installed in a storm drain one must subseque...

Page 3: ...et port 2 Outlet port 3 Terminal box 4 Motor cover 5 Motor body 6 Pump bracket 7 Ca 8 9 Pressure tank 10 Flexible hose 11 Pressure guage 12 5 Way connector 13 Pressure swith Pump body ble 1 2 3 7 5 6...

Page 4: ...Terminal box protection IP55 Insulation class Operating range from 5 to 60 l min with head up to 45 metres Liquid quality requirements clean free from solids or abrasive substances non viscous non ag...

Page 5: ...0 5 1 1 5 2 2 5 3 3 5 4 H ft H m P kPa 100 200 300 400 500 0 0 5 10 5 10 15 IMP gpm US gpm TWP37501 UTWP37501 TWP47501 UTWP47501 TWP311001 UTWP311001 TWP411001 UTWP411001 TWP315001 UTWP315001 TWP41500...

Page 6: ...le Single Single Single Rated output kW Hp 0 75 1 0 0 75 1 0 1 1 1 5 1 1 1 5 No load speed min 2850 3450 2850 3450 Capacitor uf 20 35 20 60 Max head m 45 45 60 60 Max suction m 9 9 9 9 9 9 Max flow L...

Page 7: ...OPERATION INSTRUCTION 7...

Page 8: ...in on the apertures thus preventing deformations or breakages Fig C 1 4 It is always good practice to place the pump as close as possible to the liquid to be pumped The pump must be installed only in...

Page 9: ...provided with built in thermal overload protection and may be connected directly to the mains Three phase motors must be protected with an automatic switch e g overload protection set at the values o...

Page 10: ...slackening the respective screws and slip off the cable which is now disconnected Section of cable from the pressure switch to the terminal board unscrew the nut from the cover of the pressure switch...

Page 11: ...mp does not prime A The intake pipe or the foot valve is taking in air B The downward slope of the intake pipe favours the formation of air pockets A Eliminate the phenomenon and prime again B Correct...

Page 12: ...ption 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Rotor shaft Bearing Terminal block Gasting with wound stator Bolt Screw Fairlead Screw Cable presser Terminal cover Capacitor Driving cap Tie rod...

Page 13: ...13 Exploding view TWP37501 TWP311001 TWP315001 TWP47501 TWP411001 TWP415001 UTWP37501 UTWP311001 UTWP315001 UTWP407501 UTWP411001 UTWP415001...

Page 14: ...SELF PRIMING JET PUMP T1116 V07 MADE IN CHINA www totaltools cn TOTAL TOOLS CO LIMITED One Stop Tools Station...