8
Maintenance and troubleshooting
Maintenance
•
Make sure the tool is unplugged from power before performing any maintenance.
•
Your power tool requires no additional lubrication or maintenance. Always store
your power tool in a dry place.
•
If the power cord is damaged, it must be replaced by the manufacturer, its dealer,
or qualified persons in order to avoid a hazard or damage.
Cleaning
•
Keep safety devices, ventilation slots, and the motor housing as free of dirt and
dust as possible. Wipe clean with a clean cloth or clean with low pressure
compressed air.
•
We recommend that you always clean the tool immediately after use.
•
Clean the tool regularly by wiping it down with a damp cloth and a little mild soap.
Do not use cleaners or solvents; these will attack the plastic parts of the tool. You
also need to make sure that water does not get inside.
Carbon brushes
•
If there are too many sparks, you should have the carbon brushes checked by an
authorized servicer.
Attention
Only an authorized service can change the brushes.
Problem solving
1. The operation switch is on, but the motor does not work.
o
The cables of the mains plug or the socket outlet are loose.
Check or repair the plug and outlet.
o
The switch is faulty.
Replace switch.
2. The operation switch is on, but unusual noises can be heard, the motor does not
run or runs very slowly.
o
The switch contact has failed.
Replace switch.
o
Stuck component.
Check or repair the power tool.
o
Too much thrust, as a result the motor is dragging.
Use less thrust during the task.
3. The engine gets hot.
o
Foreign substances have entered the motor.
Remove and clean foreign substances.
o
Missing grease or lubricating grease in poor condition.
Apply or change lubricating grease.
o
Pressure too high.
Use less thrust during the task.
4. Frequent or strong sparks in the commutator.
o
Short circuit in the armature.
Replace the armature.
o
Carbon brushes worn or stuck
Check carbon brushes.
o
Irregular switch operation.
Clean or grind commutator surface.
Summary of Contents for TS3006