9
. Possible causes of failure
Problem
Cause
Solution
The compressor does not start
1. No supply voltage
1. Check the supply voltage, the power plug and
the socket-outlet.
2. Insufficient supply voltage
2. Make sure that the extension cable is not too
long. Use an extension cable with large
enough wires.
3. Outside temperature is too low
3. Never operate with an outside temperature of
below +5°C.
4. Motor is overheated
4. Allow the motor to cool down. If necessary,
remedy the cause of the overheating.
The compressor starts but there is no pressure
1. Leak in the non-return valve
1. Replace the non-return valve
2. The seals are damaged.
2. Check the seals and have any damaged seals
replaced by a service center
3. The drainage screw for
condensation water (4) leaks.
3. Tighten the screw by hand. Check the seal on
the screw and replace if necessary.
The compressor starts, pressure is shown on the
pressure gauge, but the tools do not start.
1. Loose hose connections
1. Check the compressed air hose and tools and
replace if necessary.
2. Leak in a quick-lock coupling
2. Check the quick-lock coupling and replace if
necessary.
8
. Disposal and recycling
The unit is supplied in packaging to prevent its being dam-
aged in transit. This packaging is raw material and can
therefore be reused or can be returned to the raw material
system.
The unit and its accessories are made of various types of
material, such as metal and plastic. Defective components
must be disposed of as special waste.
Summary of Contents for TC120242
Page 1: ...AIR COMPRESSOR TC120242 UTC120242 TC125502 UTC125502...
Page 4: ...1 11 10 3 12 1 5 4 6 9 8 2 13 2 3 11 12 8 13 9 1 6 7...
Page 12: ...TC120242 UTC120242 Exploding view...
Page 13: ...TC120242 UTC120242 Exploding view...
Page 15: ...AIR COMPRESSOR T0512 V01 MADE IN CHINA www totaltools cn TOTAL TOOLS CO LIMITED...