![Totai 16/DK1025 Instructions For Use And Assembly Download Page 3](http://html1.mh-extra.com/html/totai/16-dk1025/16-dk1025_instructions-for-use-and-assembly_1138689003.webp)
-
-
3
C E I L I N G
W
A
L
L
100 cm
100 cm
Fortification of base to the ground
Use a 9 kg LPG cylinder only
The hose must comply with the requirements of SANS 1156-2 or BS 2312
A dented, rusted or damaged LPG cylinder may be hazardous and should not be used
Never use a cylinder with a damaged valve connection
The cylinder valve must have a horizontal outlet with a G5/8 left hand thread to suit the regulator
Never connect the cylinder directly to the heater . A regulator must always be used
The regulator must comply with the requirements of SANS 1237.
The heater is for outdoor use only. Always ensure that adequate fresh air
ventilation is provided.
Always maintain proper clearance to combustible materials, i.e. top 100 cm
and sides 100 cm minimum.
Heater must be placed on level firm ground.
Never operate heater in an explosive atmosphere like in areas where petrol or
other flammable liquids or vapours are stored.
To protect heater from strong wind, anchor the base securely to the ground
with screws.
HEATER STAND AND LOCATION
GAS REQUIREMENTS
LEAKAGE TEST
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness
check must be performed at the installation site due to possible mishandling in shipment or excessive
pressure being applied to the heater.
Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with a
spray bottle, brush or rag. Soap bubbles will appear in case of a leak.
The heater must be checked with a full cylinder.
Make sure the safety control valve is in the OFF position.
Turn the gas supply ON.
In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and re-
check.
Never leak test while smoking.