STEP 4

4-1. Fit the gas hose/pipe nut to the burner gas inlet connector.

4-2. Tighten the gas hose/pipe nut and gas inlet thread.

4-3. Fix the completed burner unit to the post by 4 pcs M6 x 10 mm bolts.

STEP 5

STEP 6-1

5-1. Check whether the connection of vertical post and burner are

assembled according to instructions, and all bolts and nuts

are tightened.

5-2. Put washer Ø8 mm on each reflector support bolt.

6-2. Fasten the reflector with 3 pcs washers and 3 pcs M8 mm dome nuts.

- 8 -

STEP 4

Bolt

STEP 5

STEP 6-2

Reflector

Wing nut

Reflector Spacer

4 SLICES ALU.REFLECTOR INSTALLATION

Warning: remove protective cover before assemble.

6-1

Summary of Contents for 16/DK1021A

Page 1: ...the vicinity of this or other any other appliance Any LPG cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING HAZARDOUS FIRE OR EXPLOSION MAY RESU...

Page 2: ...ol panel or top canopy re ector Control compartment burner and circulation air passageways must be kept clean Frequent cleaning may be necessary as required The LPG Cylinder should be turned off when...

Page 3: ...re petrol or other ammable liquids or vapours are stored To protect heater from strong wind anchor the base securely to the ground with screws HEATER STAND AND LOCATION GAS REQUIREMENTS LEAKAGE TEST G...

Page 4: ...can be watched and checked from the small round window with sliding lid located at the bottom of the flame screen to the left or right side of the controller If the pilot flame does not light or it go...

Page 5: ...burner to keep it clean and safe for use Cover the burner unit with the optional protective cover when the heater is not in use PARTS AND SPECIFICATIONS 5 2222 mm 2003 mm 765 mm 813 mm 460 mm Re ecto...

Page 6: ...oap solution for leakage test Parts supplied Assembly post with 3 pcs post brackets Reflector 813 mm with 9 pcs 8 mm washers 3 pcs M8 castle nut and 3 pcs M8 burner reflector support bolt 4 pcs bolts...

Page 7: ...n the picture 1 2 Use 3 pcs M8 x 16 mm bolts to join the post brackets and stand STEP 2 2 1 Put the post on the top of 3 pcs post brackets 2 2 Use 6 pcs M6 x 35 mm bolts and nuts to connect the post t...

Page 8: ...1 5 1 Check whether the connection of vertical post and burner are assembled according to instructions and all bolts and nuts are tightened 5 2 Put washer 8 mm on each reflector support bolt 6 2 Faste...

Page 9: ...on the post plate Connect the regulator to the gas cylinder and tighten it with adjustable wrench Put LPG cylinder on the stand Connect the end thread of inlet gas hose to the regulator STEP 7 7 1 7...

Page 10: ...linder is near empty Gas pressure is low LPG cylinder is near empty Ori ce blocked Remove clean and replace Control knob not ON Turn knob to ON Thermocouple bad Replace Thermocouple Burner will not li...