65
Installation and Maintenance
Service Manual
Steps
Procedure
middle isolation
sheet
Remove screws connecting middle isolation sheet
and support plate of condenser, chassis, and then
remove the middle isolation sheet.
13. Remove compressor
compressor
Remove the 3 foot nuts fixing compressor and then lift
the compressor upwards to remove the compressor
and damping cushion.
Note:
Keep the ports of discharge pipe and suction pipe from
foreign objects.
Remove 4 screws fixing reactor sub-assy and motor
support, and then remove the reactor sub-assy.
14. Remove the reactor
reactor
1 5. Remove middle isolation sheet