1 Working principle

The air of indoor sucked in by the cross flow fan of the air curtain, blown down to the floor at a high 

speed. And the downward airflow formed an invisible“wall”.

The air curtain is usually installed on the upside of the door the window, when the door or the window 

is opened, the airflow of the air curtain could isolate the air of the indoor side and outdoor side effectively. 
Thus the cool air leaking of the indoor side can be reduced, and can prevent the mosquitoes and dust from 
entering into the room as well.

The length of air curtain should be consonance with the width of the door or the window, put two sets 

of unit or more side by side to cover the width of the door or window entirely. 

In order to obtain more effective efficiency, the air outer of the air curtain should be paralleled with the 

door head, ensure that the speed of airflow which arrived at the floor should be more than 2.5meters/sec.

2 Specification

Model

Length

(mm)

Diameter of 

impeller(mm) Power supply

Power

input(W)

Noise

dB(A)

Weigh

(kg)

W×D×H

(mm×mm×mm)

TFM125-9K

900

125

220-240V~ 

50Hz/60Hz

110

59

16

900×206×215

TFM125-12K

1200

125

220-240V~ 

50Hz/60Hz

140

61

20

1200×206×215

TFM125-15K

1500

125

220-240V~ 

50Hz/60Hz

180

61

25

1500 X206X215

3 Installation

The installing location should be firm enough, free of vibration. The unit cannot be installed in the damp 

or the water-leaking place and should avoid the directly lighting of sunlight.

Installation method:
(1) Take out the wall-mounted frame, put it attach to the wall, to confirm the installation position of the 

bolt hole and to make the mark on it.

(2) To drill the expansion bolt hole on the marked position.
(3) To fix the wall-mounted frame on the wall with 8pcs M10 expansion bolt, the installation must be 

firm and reliable.

(4) Hang the unit on the wall-mounted frame, and screw down the 4pcs bolt under the unit.
(5) To check whether the unit is well installed, the body level and pluged in.
(6) The dimension diagram for hole position of wall-mounted frame was shown in below (Unit:mm):

Model

A

B

C

TFM125-9K

160

800

870

TFM125-12K

160

1100

1170

TFM125-15K

160

1400

1470

Notes:
(1) 

Please install unit on the indoor side.

(2) Do not install or use the unit in place where:

1) Freezing may occur.
2) Steam is produced.
3) Remarkable dust is produced.
4) Oil smoke is produced.
5) Explosive dust or gas exist.
6) Corrosive gas is produced.
7) It is splashed by water.

(3) Please install the unit horizontally, make the air outlet downward vertically.
(4) Install the unit in sturdy place free of vibration.
(5) In order to prevent accident of electric shock, make sure that earthed well.
(6) Provide an electric leakage breaker and air-break switch should be installed at the power supply 

side.

(7) The Air Curtain is to be installed so that the blades are more than 2.3m above the floor.
(8) The place where the AIR CURTAIN is to be installed must be taken to avoid the black flow of gases 

into the room from the open flue of gas or other fuel-burning appliance.

(9) It is necessary to have the plug accessible after installation.
(10) The minimum distance between the various parts of the appliance and the surrounding structure is 

300mm.

4 Circuit diagram

Power:220-230V~ 50/60Hz

L
N
PE

BN(BK)
BU(WH)
YE/GN(GN)

AC-L
AC-N

FAN-H
FAN-L
AC-N

YE/GN

BU

AP1

BN

RD

AP2

C

E

FAN MOTOR

WH

CN1

CN1

CN3

CN2

BK

TC

POWER TRANSFORMER

Air Curtain Owner's Manual