Table 3
Item
Model
Size of Fitting
Pipe(Inch)
Max.
Pipe
Length
(m)
Max. Height
Difference between
Indoor Unit and
Outdoor Unit (m)
Drainage
pipe(Outer
Diameter × wall
thickness) (mm)
Liquid
Gas
20
20
30
15
Φ25×1.5
TM18H
B
KDI
TM12H
B
KDI
15
TM24H
B
KDI
15
The connection pipe should be insulated with proper water-proof insulating material.
The pipe wall thickness shall be 0.5-1.0mm and the pipe wall shall be able to withstand the
pressure of 6.0 MPa. The longer the connecting pipe, the lower the cooling and heating effect
performs.
4.4 Electrical Requirement
Electric Wire Size and Fuse Capacity.
Table 4
Indoor Units
Power Supply
Fuse Capacity Min. Power Supply Cord
V/Ph/Hz
208-230V~ 60Hz
A
5
mm
2
12~24k
AWG 18
Notes:
①
.
The fuse is located on the main board.
②
.
Install the disconnect device with a contact gap of at least 3mm in all poles nearby the units
(Both indoor unit and outdoor unit).The appliance must be positioned so that the plug is
accessible.
③
.
based on the maximum power (maximum amps) of the unit.
④
.
guarded multi-wire copper cable (like, YJV copper cable, consisting of PE insulated wires and
a PVC cable jacket) used at
40°С
and resistible to
90°С(see
IEC 60364-5-52). If the working
DC Inverter Free match Series Cassette Type Unit
Ф3/
8
Ф5/8
Ф1/4
Ф3/8
Ф1/2