172
WX9 ASD Installation and Operation Manual
ASD Number
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
assigning an identification (ID) number to each ASD in the communications
network.
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the parameter settings of the ASD.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
Direct Access Number — F802
Parameter Type —
Numerical
Factory Default —
0
Changeable During Run —
Yes
Minimum — 0
Maximum — 255
Communications Time-Out RS232/RS485
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
setting the time that no activity may exist over the communications link before
the link is severed (Time-Out).
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the settings of the ASD.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
Direct Access Number — F803
Parameter Type —
Numerical
Factory Default —
0
Changeable During Run —
Yes
Minimum — 0
Maximum — 100
Units — Seconds
Communications Time-Out Action (RS232/RS485 and TTL)
Program
Communications
Communication Settings
This parameter plays a role in the setup of the communications network by
determining the action to be taken in the event of a time-out (Time-Out Action).
The communications network includes other ASDs and Host/Control computers
that monitor the status of the ASD(s), transfers commands, and loads or
modifies the settings of the drive.
Note:
Changes made to this parameter require that the power be cycled
(off then on) for the changes to take effect.
Settings:
Direct Access Number — F804
Parameter Type —
Selection List
Factory Default —
Trip
Changeable During Run —
Yes
Setting
RS232/RS485
nTTL
0
No action
No action
1
Alarm
No action
2
Trip
No action
3
No action
Alarm
4
Alarm
Alarm
5
Trip
Alarm
6
No action
Trip
7
Alarm
Trip
8
Trip
Trip
Summary of Contents for WX9 ASD
Page 2: ......
Page 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Page 4: ......
Page 12: ...iv WX9 ASD Installation and Operation Manual ...
Page 225: ......