ELECTRICAL ADJUSTMENTS
D3-3
2-12: WHITE BALANCE
NOTE: Adjust after performing CUT OFF adjustment.
1.
2.
3.
4.
5.
6.
7.
Place the set with Aging Test for more than 15 minutes.
Receive the gray scale pattern from the Pattern
Generator.
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (03) on the remote control to
select "R DRIVE".
Press the CH. UP/DOWN button on the remote control
to select the "R DRIVE", "G DRIVE", "M R CUTOFF" or
"M G CUTOFF".
Adjust the VOL. UP/DOWN button on the remote control
to whiten the R DRIVE, G DRIVE, M R CUT OFF, and M
G CUT OFF at each step tone sections equally.
Perform the above adjustments 5 and 6 until the white
color is looked like a white.
2-13: BRIGHT CENT
1.
2.
3.
4.
5.
6
Receive the PAL black pattern*. (RF Input)
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (17) on the remote control to
select "BRIGHT CENT".
Press the VOL. UP/DOWN button on the remote control
until the screen begin to shine.
Receive the PAL black pattern*. (Audio Video Input)
Press the AV button on the remote control to set to the
AV mode. Then perform the above adjustments 2~4.
*The Black Pattern means the whole black raster signal.
Select the "RASTER" of the pattern generator, set to
the OFF position for each R, G and B.
2-14: CONTRAST CENT
1.
2.
3.
4.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (20) on the remote control to
select "CONTRAST CENT".
Press the VOL. UP/DOWN button on the remote control
until the contrast step No. becomes "24".
Receive a broadcast and check if the picture is normal.
Press the AV button on the remote control to set to the
AV mode. Then perform the above adjustments 1~3.
2-16: COLOR CENT
1.
2.
3.
4.
5.
6.
7.
8.
Receive the PAL color bar pattern. (RF Input)
Using the remote control, set the brightness, contrast
and color to normal position.
Connect the oscilloscope to TP803.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (23) on the remote control to
select "COLOR CENT".
Adjust the VOLTS RANGE VARIABLE knob of the
oscilloscope until the range between white 100% and
0% is set to 4 scales on the screen of the oscilloscope.
Press the VOL. UP/DOWN button on the remote control
until the red color level is adjusted to 90
±
5% of the
white level. (Refer to Fig. 2-3)
Receive the PAL color bar pattern. (Audio Video Input)
Press the AV button on the remote control to set to the
AV mode. Then perform the above adjustments 2~6.
Fig. 2-3
90%
100%
2-15: SUB SHARPNESS
1.
2.
3.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (27) on the remote control to
select "SHARPNESS".
Press the VOL. UP/DOWN button on the remote control
until the contrast step No. becomes "05".
Press the AV button on the remote control to set to the
AV mode. Then perform the above adjustments 1~2.
2-17: Confirmation of Fixed Value (Step No.)
Please check if the fixed values of the each adjustment
items are set correctly referring below.
NO.
02
04
06
07
15
16
18
19
21
22
24
25
30
35
36
37
38
FUNCTION
AGC GAIN
R CUTOFF
G CUTOFF
B DRIVE
VCO COARSE L1
VCO FINE L1
BRIGHT MAX
BRIGHT MIN
CONTRAST MAX
CONTRAST MIN
COLOR MAX
COLOR MIN
M B CUT OFF
CVBS OUT
APR THRESHOLD
BELL FILTER
BANDPASS
RF (50Hz)
00
31
31
31
00
00
55
20
40
10
60
10
50
10
15
00
00